Name ID Label Description Type Access Class
flow_units 1F7B PV unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 32
flow_value 1F7C PV Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R Float 34
flow_analog_value 1F7D PV AO Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes R/W Float 34
flow_percent_range 1F7E PV % rnge Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
dummy_float_value1 4003 Dummy float value R Float 32
dummy_float_value2 4004 Dummy float value R Float 32
dummy_float_value3 4005 Dummy float value R Float 32
dummy_float_value4 4009 Dummy float value R/W Float 32
dummy_3integer_value 4006 Dummy Integer3 Value R Unsigned 2048
flow_alarm_select 1F83 4-20mA Burn Out Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R Enum 64
dummy_transfer_func 4007 Dummy transfer function R Enum 2048
flow_span_disp 4008 PV Span Sets flow rate span (with units from "Base Flow Unit" and "Base Time Unit"). R/W Float 32
flow_damping_value 1F87 PV Damping Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 32
flow_total_units 400B Total Unit R Enum 32
flow_total_value 400C Totl Displays the totalized value for flow rate in the forward direction. R Float 34
rev_total_units 400E Reverse Totl Units R Enum 32
rev_total_value 400F Reverse Totl Displays the totalized value for flow rate in the reverse direction. R Float 34
dif_total_units 4010 Dif Totl Units R Enum 32
dif_total_value 4011 Dif Totl Displays the totalized value for flow rate between forward totalization and reverse totalization. R Float 34
select_flow_tube 4012 Select Flow Tube Selects the flowtube's model name. R/W Enum 2048
nominal_size_unit 4013 Nominal Size Unit Selects the nominal size units for the flowtube. R/W Enum 2048
nominal_size 4014 Nominal Size Sets flowtube nominal size in selected unit at "Nominal Size Unit". R/W Float 2048
measure_mode 4015 Measure Mode Selects measurement mode for dual frequency excitation. R/W Enum 2048
low_mf 4016 Low MF Sets low-frequency meter factor for standard dual frequency excitation. R/W Float 2048
high_mf 4017 High MF Sets high-frequency meter factor for standard dual frequency excitation. R/W Float 2048
low_mf_edf 4018 Low MF(EDF) Sets low-frequency meter factor for enhanced dual frequency excitation. R/W Float 2048
high_mf_edf 4019 High MF(EDF) Sets high-frequency meter factor for enhanced dual frequency excitation. R/W Float 2048
span_unit 401A Span Unit R Enum 2048
pv_span 401B PV Span Sets flow rate span (with units from "Base Flow Unit" and "Base Time Unit"). R/W Float 32
base_flow_unit 401C Base Flow Unit Selects flow units for the flow rate span. R/W Enum 2048
base_time_unit 401D Base Time Unit Selects time units for the flow rate span. R/W Enum 2048
flow_decimal_point 401E Flow Decimal Pnt Selects decimal point position for the display unit's instantaneous flow rate. R/W Enum 2048
density_unit 401F Density Unit Sets units for density when mass flow rate is selected. R/W Enum 2048
mass_flow_density 4020 Mass Flow Density Sets density when mass flow rate is selected (with units from "Density Unit"). R/W Float 2048
user_span_select 4021 User Span Select Selects whether or not special units are used as flow rate units. R/W Enum 2048
user_flow_unit 4022 Flow User Unit Sets the special flow rate units. R/W ASCII 2048
user_flow_span 4023 Flow User Span Sets span when using special flow rate units. R/W Float 2048
analog_low_cut 4024 4-20mA Low Cut Sets the range in vicinity of 0 % within which the current output will be 4 mA. R/W Float 2048
analog_low_lmt 4025 4-20mA Low Lmt Sets the low limit for current output. R/W Float 2048
analog_high_lmt 4026 4-20mA High Lmt Sets the high limit for current output. R/W Float 2048
velocity_check 4027 Velocity Check Display of the span setting using flow velocity (m/s). R Float 2050
magflow_zero 4028 Magflow Zero Displays the result of the automatic zero adjustment, or sets the zero point. R/W Float 2048
autozero_time 4029 Autozero Time R/W Integer 2048
auto_zero_exe 402A Auto Zero Exe Selects whether or not automatic zero adjustment is carried out. R Enum 2048
disp_select1 402B Display Select1 Selects content of the first line for Display Mode. R/W Enum 2048
disp_select2 402C Display Select2 Selects content of the second line for Display Mode. R/W Enum 2048
disp_select3 402D Display Select3 Selects content of the third line for Display Mode. R/W Enum 2048
disp_cycle 402E Display Cycle Selects the display cycle. R/W Enum 2048
lcd_contrast 402F LCD Contrast R/W Integer 2048
language 4030 Language Selects the language used for the display unit. R/W Enum 2048
Name ID Label Description Type Access Class