Name ID Label Description Type Access Class
flow_units 1F7B PV unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 32
flow_value 1F7C PV Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R Float 34
flow_analog_value 1F7D PV AO Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes R/W Float 34
flow_percent_range 1F7E PV % rnge Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
dummy_float_value1 4003 Dummy float value R Float 32
dummy_float_value2 4004 Dummy float value R Float 32
dummy_float_value3 4005 Dummy float value R Float 32
dummy_float_value4 4009 Dummy float value R/W Float 32
dummy_3integer_value 4006 Dummy Integer3 Value R Unsigned 2048
flow_alarm_select 1F83 4-20mA Burn Out Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. R Enum 64
dummy_transfer_func 4007 Dummy transfer function R Enum 2048
flow_span_disp 4008 PV Span Sets flow rate span (with units from "Base Flow Unit" and "Base Time Unit"). R/W Float 32
flow_damping_value 1F87 PV Damping Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. R/W Float 32
flow_total_units 400B Total Unit R Enum 32
flow_total_value 400C Totl Displays the totalized value for flow rate in the forward direction. R Float 34
rev_total_units 400E Reverse Totl Units R Enum 32
rev_total_value 400F Reverse Totl Displays the totalized value for flow rate in the reverse direction. R Float 34
dif_total_units 4010 Dif Totl Units R Enum 32
dif_total_value 4011 Dif Totl Displays the totalized value for flow rate between forward totalization and reverse totalization. R Float 34
select_flow_tube 4012 Select Flow Tube Selects the flowtube's model name. R/W Enum 2048
nominal_size_unit 4013 Nominal Size Unit Selects the nominal size units for the flowtube. R/W Enum 2048
nominal_size 4014 Nominal Size Sets flowtube nominal size in selected unit at "Nominal Size Unit". R/W Float 2048
measure_mode 4015 Measure Mode Selects measurement mode for dual frequency excitation. R/W Enum 2048
low_mf 4016 Low MF Sets low-frequency meter factor for standard dual frequency excitation. R/W Float 2048
high_mf 4017 High MF Sets high-frequency meter factor for standard dual frequency excitation. R/W Float 2048