Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
flow_units | 1F7B | PV unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 32 |
flow_value | 1F7C | PV | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention | R | Float | 34 |
flow_analog_value | 1F7D | PV AO | Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes | R/W | Float | 34 |
flow_percent_range | 1F7E | PV % rnge | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 34 |
dummy_float_value1 | 4003 | Dummy float value | R | Float | 32 | |
dummy_float_value2 | 4004 | Dummy float value | R | Float | 32 | |
dummy_float_value3 | 4005 | Dummy float value | R | Float | 32 | |
dummy_float_value4 | 4009 | Dummy float value | R/W | Float | 32 | |
dummy_3integer_value | 4006 | Dummy Integer3 Value | R | Unsigned | 2048 | |
flow_alarm_select | 1F83 | 4-20mA Burn Out | Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. | R | Enum | 64 |
dummy_transfer_func | 4007 | Dummy transfer function | R | Enum | 2048 | |
flow_span_disp | 4008 | PV Span | Sets flow rate span (with units from "Base Flow Unit" and "Base Time Unit"). | R/W | Float | 32 |
flow_damping_value | 1F87 | PV Damping | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. | R/W | Float | 32 |
flow_total_units | 400B | Total Unit | R | Enum | 32 | |
flow_total_value | 400C | Totl | Displays the totalized value for flow rate in the forward direction. | R | Float | 34 |
rev_total_units | 400E | Reverse Totl Units | R | Enum | 32 | |
rev_total_value | 400F | Reverse Totl | Displays the totalized value for flow rate in the reverse direction. | R | Float | 34 |
dif_total_units | 4010 | Dif Totl Units | R | Enum | 32 | |
dif_total_value | 4011 | Dif Totl | Displays the totalized value for flow rate between forward totalization and reverse totalization. | R | Float | 34 |
select_flow_tube | 4012 | Select Flow Tube | Selects the flowtube's model name. | R/W | Enum | 2048 |
nominal_size_unit | 4013 | Nominal Size Unit | Selects the nominal size units for the flowtube. | R/W | Enum | 2048 |
nominal_size | 4014 | Nominal Size | Sets flowtube nominal size in selected unit at "Nominal Size Unit". | R/W | Float | 2048 |
measure_mode | 4015 | Measure Mode | Selects measurement mode for dual frequency excitation. | R/W | Enum | 2048 |
low_mf | 4016 | Low MF | Sets low-frequency meter factor for standard dual frequency excitation. | R/W | Float | 2048 |
high_mf | 4017 | High MF | Sets high-frequency meter factor for standard dual frequency excitation. | R/W | Float | 2048 |
Name | ID | Label | Description | Type | Access | Class |