Loading…
Name ID Label Description Type Access Class
total_decimal_point 400D Total Decimal Pnt Selects position of decimal point for totalization display. R/W Enum 2048
pulse_unit 403B Pulse Unit Selects the flow rate unit per one pulse as used for pulse output. R/W Enum 2048
pulse_scale 403C Pulse Scale Sets the flow rate per one pulse as used for pulse output. R/W Float 2048
pulse_low_cut 403D Pulse Low Cut Sets the range in vicinity of 0% within which pulse output will be halted. R/W Float 2048
pulse_width 403E Pulse Width Selects the pulse width for pulse output. R/W Enum 2048
pulse_active_mode 403F Pulse Active Mode R/W Enum 2048
tp_damping_select 4040 T/P Damp Select Selects whether the flow rate value obtained through damping calculation for total/pulse or the instantaneous flow rate value (no damping) for total/pulse is to be used. R/W Enum 2048
flow_direction 4041 Flow Direction Selects the flow direction. R/W Enum 2048
rate_limit 4042 Rate Limit Sets the level to reduce output fluctuation. R/W Float 2048
dead_time 4043 Dead Time Sets the dead time to reduce output fluctuation. When "0" is set, rate limit function is not available. R/W Float 2048
Name ID Label Description Type Access Class