Loading…
Name ID Label Description Type Access Class
sensorValue 4000 Sensor Value Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention R Float 2
sensorUnits 4001 Sensor Units Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit R/W Enum 0
sensorFamily 4002 Sensor Fmaily Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. R Enum 0
sensorClassification 4003 Sensor Class Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. R Enum 0
sensorPDQ 4004 Sensor PDQ Process Data Quality- Indicates the overall process data quality of the device variable value. R Enum 2
sensorLS 4005 Sensor LS Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). R Enum 2
sensorStatus 4006 Sensor Status Device Family Status- Indicates additional status information on a device variable for a specific device family. R BitEnum 2
sensorUSL 4007 Sensor USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 0
sensorLSL 4008 Sensor LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 0
sensorMinimumSpan 4009 Sensor Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 0
Name ID Label Description Type Access Class