Name ID Label Description Type Access Class
varDeviceName 411C Device name R ASCII 2048
varApprovalWhg 411D Sensor acc. to WHG Use as a part of an overfill protection system according to WHG R/W Enum 2048
varFirmwareVersion 411E Software version Version of the instrument software R Unsigned 4096
varManufacturerId 411F Manufacturer ID R Unsigned 2048
varDeviceTypeId 4120 Expanded Device Type Identification of the instrument type through Fieldbus R Unsigned 2048
varBusTypeId 4121 Bustype ID R Unsigned 2048
varMeasurementPrinciple 4122 Sensor type R Unsigned 2048
varSerialnumber 4123 Serial number R Unsigned 2048
varDTM_ID 4080 DTM ID R Unsigned 2048
varDeviceRev 4124 Device-Revision Compatibility information for integration into the device catalogue R Unsigned 2048
varPin 4125 PIN Determine the PIN which should be valid for the function 'Lock adjustment' R/W Unsigned 2048
varDisplayConfig_PictureSelection 4088 Graph Selection of the presentation for the measured value image R/W Enum 2048
varDisplayConfig_DisplayedValue 4126 Indication value 1 Determines which measured value should be displayed R/W Enum 2048
varDisplayConfig_Language 4129 Menu language Selection of the language for the indicating and adjustment module R/W Enum 2048
varDisplayConfig_IluminationActivation 412A Lighting Activation of the background lighting of the indicating and adjustment module R/W Enum 2048
varDisplayConfig_DisplayedValue2 412B Indication value 2 Determines which measured value should be displayed R/W Enum 2048
varScaling_MinScaledValue 412C 0 % corresponds to Scaled value for 0 % R/W Float 2048
varScaling_MaxScaledValue 412E 100 % corresponds to Scaled value for 100 % R/W Float 2048
varScaling_ScalingUnit 412F Scaling unit Measuring unit for the scaled value R/W Enum 2048
varScaling_DecimalPlacesDisplay 412D Scaling format Determination of the presentation of decimal points R/W Enum 2048
varApplicationConfigPressure_ActiveApplication 4081 Selection of the application By selecting the application, the sensor can be adapted to the measurement task R/W Enum 2048
varIntegrationTime_ResponseTime 4134 Integration time (t) Damping of measured value peaks R/W Float 2048
varDeviceUnits_PhysicalValueUnit 4127 Adjustment unit of the instrument Selection of the physical unit for indication and parameter adjustment R/W Enum 2048
varDeviceUnits_TemperatureUnit 4136 Temperature unit of the instrument Selection of the physical temperature unit for indication and parameter adjustment R/W Enum 2048
varLinearisationTypeSel 408F Linearization type Selection of the linearization curve R/W Enum 2048
varLinarizationCurve_VesselHeight 4138 Vessel height D Total height (inner dimension) R/W Float 2048
varLinarizationCurve_SensorZeroToVesselTopDistance 413B Socket correction h Distance of the sensor reference plane to the upper edge of the vessel R/W Float 2048
varLinTabX0 413E 1 R/W Float 2048
varLinTabX1 413F 2 R/W Float 2048
varLinTabX2 4140 3 R/W Float 2048
varLinTabX3 4141 4 R/W Float 2048
varLinTabX4 4142 5 R/W Float 2048
varLinTabX5 4143 6 R/W Float 2048
varLinTabX6 4144 7 R/W Float 2048
varLinTabX7 4145 8 R/W Float 2048
varLinTabX8 4146 9 R/W Float 2048
varLinTabX9 4147 10 R/W Float 2048
varLinTabX10 4148 11 R/W Float 2048
varLinTabX11 4149 12 R/W Float 2048
varLinTabX12 414A 13 R/W Float 2048
varLinTabX13 414B 14 R/W Float 2048
varLinTabX14 414C 15 R/W Float 2048
varLinTabX15 414D 16 R/W Float 2048
varLinTabX16 414E 17 R/W Float 2048
varLinTabX17 414F 18 R/W Float 2048
varLinTabX18 4150 19 R/W Float 2048
varLinTabX19 4151 20 R/W Float 2048
varLinTabX20 4152 21 R/W Float 2048
varLinTabX21 4153 22 R/W Float 2048
varLinTabX22 4154 23 R/W Float 2048
Name ID Label Description Type Access Class