Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
varOffsetCustomer_Value | 418E | Offset | Direct adjustment of the offset for compensation of the mounting position | R/W | Float | 2048 |
varConfigInterfaceMeasuring_DensityUpperMedium | 418F | Density upper medium | Requirement for the interface measurement is that both sensors are covered by the medium. The interface can only be detected between the two sensors. | R/W | Float | 2048 |
varConfigInterfaceMeasuring_DensityLowerMedium | 4191 | Density lower medium | Requirement for the interface measurement is that both sensors are covered by the medium. The interface can only be detected between the two sensors. | R/W | Float | 2048 |
varConfigInterfaceMeasuring_DistanceBetweenSensors | 4192 | Distance of the sensors (A) | The distance of the two sensors must be entered for determination of the interface out of the measured differential pressure | R/W | Float | 2048 |
varConfigDensityMeasuring_DistanceBetweenSensors | 4193 | Distance of the sensors (A) | The distance of the two sensors must be entered for determination of the density out of the measured differential pressure | R/W | Float | 2048 |
varDeviceHardwareVersionAscii_VersionInfoAscii | 4194 | Hardware version | Hardware version of the main electronics | R | ASCII | 2048 |
varDeviceSoftwareVersionAscii_VersionInfoAscii | 4195 | Software version | Software version of the main electronics | R | ASCII | 2048 |
varCalibrationDate_CalibrationDay | 4196 | R | Unsigned | 2048 | ||
varCalibrationDate_CalibrationMonth | 4198 | R | Unsigned | 2048 | ||
varCalibrationDate_CalibrationYear | 4199 | R | Unsigned | 2048 | ||