Name ID Label Description Type Access Class
lock_device_status_codes 07FE R Enum 4096
analog_channel_flags 0802 R Enum 4096
process_data_status 0804 R Enum 4096
limit_status 0805 R Enum 4096
device_family_status 0806 R Enum 4096
manufacturer_id 0099 Produttore Codice identificazione produttore - Si riferisce ad un produttore specifico, solitamente il nome di una società, che è responsabile della produzione del dispositivo di campo. R Enum 0
private_label_distributor 00A8 Distributore Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers R Enum 0
device_type 009A Model Model- References the type of Field Device, usually an advertised model number, that is unique to a single manufacturer R Enum 0
write_protect 00A7 Write protect Write Protect Mode- Indicates whether variables can be written to the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. Depending on the Field Device, this is a mode that is controllable by the user, either via the Field Device hardware or the HART Protocol. R Enum 0
physical_signaling_code 00AB Physicl signl code Physical Signaling Code- The Physical Signaling Code describes the type of Physical Layer that has been implemented in the hardware that is responsible for the HART Communication port R Enum 0
operatingMode 0870 Operate mode 1 Field Device Specific Operating Mode 1- A possible mode of operation in Field Device R Enum 2049
extended_fld_device_status 0807 Ext dev status Extended Field Device Status- This provides additional Device Status information R BitEnum 0
loop_current_mode 0808 Loop current mode Modalità corrente di loop - Indica se la corrente di loop è attiva o fissa (ovvero il dispositivo è in modalità multi-drop). R/W Enum 0
device_flags 00A0 Dev flags Field Device Flags- Describes special features of the Field Device that affect the Data Link Layer R BitEnum 0
response_code 0096 Response code Command Specific Response Code- Data that is returned in the Field Device response, that indicates the relative success of the Command sent in the Host request. This information may relate to the Data of the Host request or to the command itself. R Enum 129
comm_status 0098 Communication status Communications Error Summary- The Field Device has detected the following error condition while attempting to receive the Host request. Therefore the Command was not accepted, and the Host request caused no change to occur in the Field Device. R BitEnum 131
device_status 0097 Device status Field Device Status- Data indicating that the Field Device has detected condition(s) in the Field Device relating to: its hardware / the validity of a variable / its operating status / an internal process R BitEnum 131
request_preambles 009B Num req preams Number of Request Preambles- Number of Preambles required from the Host request by the Field Device R Unsigned 128
universal_revision 009C Universal rev Universal Revision- Revision of the Universal Device Description, that the Field Device conforms to R Unsigned 128
transmitter_revision 009D Fld dev rev Field Device Revision- Revision of the Field Device Specific Device Description, that the Field Device conforms to R Unsigned 128
software_revision 009E Software rev Field Device Software Revision- This revision corresponds to the software or firmware, that is embedded in the Field Device R Unsigned 2048
hardware_revision 009F Hardware rev Versione hardware - Versione che corrisponde all’hardware dell’elettronica del dispositivo di campo. R Unsigned 2048
device_id 00A1 Dev id Field Device Identification- Uniquely identifies the Field Device when combined with the Manufacturer Identification and Device Type. Therefore, this variable cannot be modified by the Host user. R Unsigned 2048
response_preambles 0FE2 Num resp preams Number of Response Preambles- Number of Preambles to be sent in the response message from the Field Device to the Host W Unsigned 128
tag 00A3 Tag Tag - Testo associato all’installazione del dispositivo di campo. Questo testo può essere utilizzato dall’utente in qualsiasi modo. Un uso consigliato è come etichetta univoca per un impianto che si correla all’etichetta di un dispositivo di campo: un disegno dell’impianto o su un sistema di controllo. Questa variabile viene utilizzata anche come tipo di handle di indirizzo a livello di collegamento dati. R/W PackedAscii 2048
Name ID Label Description Type Access Class