Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
FlowValue | 40E0 | Flow | Flo rate | R | Float | 10 |
FlowUnits | 40E1 | Flow unit | Flo rate unit | R/W | Enum | 0 |
FoValue | 40E2 | FO | Forward flow direction total value | R | Float | 10 |
RvValue | 40E3 | RV | Reverse flow direction total value | R | Float | 10 |
DfValue | 40E4 | DF | Difference between forward and reverse total value | R | Float | 10 |
TotalUnits | 40E5 | Unit | Total flow unit | R/W | Enum | 0 |
input_percent_value | 40E6 | Percent | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 10 |
FlowLUnits | 40E7 | Limit unit | R | Enum | 0 | |
FlowUSL | 40E8 | Upper sensor limit | R | Float | 0 | |
FlowLSL | 40E9 | Lower sensor limit | R | Float | 0 | |
FlowMinimumSpan | 40EA | Minimum span | R | Float | 0 | |
pressureValue | 40EB | Pres | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 10 |
pressureUnits | 40EC | Pressure unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure | R/W | Enum | 0 |
pressureUSL | 40ED | Pres USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
pressureLSL | 40EE | Pres LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
pressureMinimumSpan | 40EF | Pres min span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 0 |
pressureDampingValue | 40F0 | Damping | Damping value is used to moderate output fluctuations. The larger damping value, the more the output is averaged. But the response to an input change will be slower.Damping value is set for 0.0sec, 0.5sec and 1 to 60sec (in increments of 1sec). | R/W | Float | 0 |
pressureSerialNumber | 40F1 | Pres snsr s/n | Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. | R | Unsigned | 2048 |
input_calibration_mode | 4027 | Calibration Mode | W | Unsigned | 32 | |
input_calibration_step | 4028 | Calibration Step | W | Unsigned | 32 | |
input_excitation_current | 4030 | Exc Curr Dsp | R | Float | 4 | |
input_low_cut_value | 400E | Low cut | Low cutoff is the function to set the current output to zero forcefully if the flow rate is equal to or less than the low cutoff value set near 0%. Low cutoff value can be set within the range 0 to 10% in increments of 0.1%. | R/W | Float | 32 |
input_excitation_frequency_code | 401B | Exc freq | Since each exciting frequency value has its own characteristics, you should select an appropriate exciting frequency (24Hz is set at shipment. Depending on the characteristics of the detector, a large frequency may result in excitation failure. When a large frequency value is set and it changes the indicator value, decrease the frequency to a value that will not change the indicator value.) | R/W | Enum | 32 |
input_pulse_rate_unit | 4017 | Unit | Unit of count rate | R/W | Enum | 32 |
input_pulse_rate | 4018 | Count rate | R/W | Float | 32 | |
input_pulse_width | 4019 | Pulse width | R/W | Unsigned | 32 | |
input_pulse_mode | 40F2 | Pulse mode | AUTO:After the count rate is set, the pulse width is automatically set to 40% of the period of pulse frequency at 100% output. MANUAL:Even after the count rate is set, the pulse width is not changed. | R/W | Enum | 32 |
input_d_size | 401C | Meter size | R/W | Unsigned | 32 | |
input_d_size_unit | 40AA | Meter size unit | R/W | Enum | 32 | |
input_signal_status_code | 401F | Alarm set1 | R/W | BitEnum | 32 | |
input_signal_status_code2 | 40F3 | Alarm set2 | R/W | BitEnum | 32 | |
input_alarm_upper_value | 401D | High alarm | R/W | Integer | 32 | |
input_alarm_lower_value | 401E | Low alarm | R/W | Integer | 32 | |
input_empty_level | 40AB | Empty alarm level | R/W | Enum | 32 | |
input_alarm_upper_value2 | 40F4 | HH alarm | R/W | Integer | 32 | |
input_alarm_lower_value2 | 40F5 | LL alarm | R/W | Integer | 32 | |
input_signal_percent_rate_limit | 4020 | Rate-of-change limit | R/W | Unsigned | 32 | |
input_signal_time_rate_limit | 4021 | Control limit time | R/W | Unsigned | 32 | |
sensor_damping_value | 4009 | Damping | Damping value is used to moderate output fluctuations. The larger damping value, the more the output is averaged. But the response to an input change will be slower.Damping value is set for 0.0sec, 0.5sec and 1 to 60sec (in increments of 1sec). | R/W | Float | 8 |
detector_serial_number | 4023 | Detector | Detector's serial number | R | PackedAscii | 2048 |
converter_serial_number | 4024 | Converter | Converter's serial number | R | PackedAscii | 2048 |
detector_spec_code | 4090 | Detector | Detector's product specification code | R | PackedAscii | 2048 |
converter_spec_code | 4091 | Converter | Converter's product specification code | R | PackedAscii | 2048 |
input_ex_curr | 408D | Exc current | Be sure to match the exciting current value with the value specified for the combined detector. Specifying any other value may cause an error. The setting range of excitation current value is from 0.0000A to 0.2500A. | R/W | Float | 32 |
input_flange_types | 4092 | Flange type | R/W | Enum | 2048 | |
LF600_liner_material | 40F6 | Lining material | R/W | Enum | 2048 | |
LF600_electrode_material | 40F7 | Electrode material | R/W | Enum | 2048 | |
connection_flgn_matl | 402C | Earthring material | R/W | Enum | 2048 | |
seal_material | 4029 | Seal matl | R/W | Enum | 2048 | |
input_pass_word | 40B4 | Password | R/W | Unsigned | 32 | |
Name | ID | Label | Description | Type | Access | Class |