Name ID Label Description Type Access Class
FlowValue 40E0 Flow Flo rate R Float 10
FlowUnits 40E1 Flow unit Flo rate unit R/W Enum 0
FoValue 40E2 FO Forward flow direction total value R Float 10
RvValue 40E3 RV Reverse flow direction total value R Float 10
DfValue 40E4 DF Difference between forward and reverse total value R Float 10
TotalUnits 40E5 Unit Total flow unit R/W Enum 0
input_percent_value 40E6 Percent Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 10
FlowLUnits 40E7 Limit unit R Enum 0
FlowUSL 40E8 Upper sensor limit R Float 0
FlowLSL 40E9 Lower sensor limit R Float 0
FlowMinimumSpan 40EA Minimum span R Float 0
pressureValue 40EB Pres Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 10
pressureUnits 40EC Pressure unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure R/W Enum 0
pressureUSL 40ED Pres USL Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
pressureLSL 40EE Pres LSL Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
pressureMinimumSpan 40EF Pres min span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. R Float 0
pressureDampingValue 40F0 Damping Damping value is used to moderate output fluctuations. The larger damping value, the more the output is averaged. But the response to an input change will be slower.Damping value is set for 0.0sec, 0.5sec and 1 to 60sec (in increments of 1sec). R/W Float 0
pressureSerialNumber 40F1 Pres snsr s/n Sensor Serial Number- Uniquely identifies the sensor from which the Digital Value representation or Field Device variable is primarily derived. R Unsigned 2048
input_calibration_mode 4027 Calibration Mode W Unsigned 32
input_calibration_step 4028 Calibration Step W Unsigned 32
input_excitation_current 4030 Exc Curr Dsp R Float 4
input_low_cut_value 400E Low cut Low cutoff is the function to set the current output to zero forcefully if the flow rate is equal to or less than the low cutoff value set near 0%. Low cutoff value can be set within the range 0 to 10% in increments of 0.1%. R/W Float 32
input_excitation_frequency_code 401B Exc freq Since each exciting frequency value has its own characteristics, you should select an appropriate exciting frequency (24Hz is set at shipment. Depending on the characteristics of the detector, a large frequency may result in excitation failure. When a large frequency value is set and it changes the indicator value, decrease the frequency to a value that will not change the indicator value.) R/W Enum 32
input_pulse_rate_unit 4017 Unit Unit of count rate R/W Enum 32
input_pulse_rate 4018 Count rate R/W Float 32