Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
DI_status_code | 402F | DI | DI- Digital input: Voltage signal input. | R/W | Enum | 2048 |
DI_det_level | 40B2 | DI det level | DI det level- Active level of digital input signal for totalizer control. [L LEVEL] Start/Stop mode; H level input: counter stop. L level input: counter start. [L LEVEL] Reset/Start mode; H level input: counter start. L level input: counter reset. [H LEVEL] Start/Stop mode; H level input: counter start. L level input: counter stop. [H LEVEL] Reset/Start mode; H level input: counter reset. L level input: counter start. | R/W | Enum | 2048 |
input_si_unit | 40B3 | SI or SI&US unit | Setting [SI & US], add US unit; [gal] [ft] and [bbl] in engineering units. | R/W | Enum | 2048 |
alarm_action | 4093 | Alarm action | Alarm action | R/W | Enum | 2048 |
input_excitation_current | 4030 | EX.CURR.DSP. | R | Float | 4 | |
input_pass_word | 40B4 | Password | Password- Security code for local programing. Enter correct password by local SW, enable parameters to change. | R/W | Unsigned | 32 |
unique_device_type_code | 07ED | R/W | Enum | 4096 | ||
rosemount_model_code | 07F5 | R/W | Enum | 4096 | ||
rosemount_analytical_model_code | 07F6 | R/W | Enum | 4096 | ||
kayray_model_code | 07F7 | R/W | Enum | 4096 | ||
Name | ID | Label | Description | Type | Access | Class |