Loading…
Name ID Label Description Type Access Class
module_fill_fluid 139E Fill fluid Sensor Fill Fluid- Fluid material in the module R Enum 2048
number_of_remote_seals 139F Num remote seal Number of Remote Seals- Physical quantity of the seals for the remote seal that is installed R/W Enum 2048
sensor_a_lower_sensor_trim_point 1774 Pres snsr LST pt Lower Sensor Trim Point- Applied process pressure at which the last low sensor trim was performed. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. R/W Float 8
sensor_a_upper_sensor_trim_point 1776 Pres snsr UST pt Upper Sensor Trim Point- Applied process pressure at which the last upper sensor trim was performed. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. R/W Float 8
sensor_a_sensor_trim_unit 1772 Pres snsr ST unit Sensor Trim Unit- Unit associated with the Sensor Lower Trim and Sensor Upper Trim. Pressure Sensor- Pressure hardware that measures pressure with respect to a reference pressure. R Enum 8
analog_output_value 1779 AO1 Out Analog Output Value- Value that tracks the Digital Value representation, under normal operating modes. Analog Output- Measurable physical output which changes with respect to time, without user intervention. R/W Float 66
analog_output_alarm_select 177A AO1 Alrm typ Analog Output Alarm Type- Defines how the Analog Output will respond when the Field Device detects that the Analog Output may not be tracking the associated Field Device Variable. NOTE- The Digital Value representation may not be determinate. Analog Output- Measurable physical output which changes with respect to time, without user intervention. R Enum 64
module_type_code 177B Meas typ Measurement Type- Type of measurement application this Field Device is intended to be used with R Enum 2048
flange_material 177C Flnge matl Flange Material- Construction material of flange type R/W Enum 2048
meter_information_configuration 177D Meter typ config Meter Information Configuration- Defines what information the meter will display R/W Enum 256
Name ID Label Description Type Access Class