Name ID Label Description Type Access Class
pipe_description 4001 Pipe desc Pipe desc -User message to describe the pipe. R/W PackedAscii 0
percent_solids_carrier 4002 Density of carrier Density of Carrier -The density of the carrier liquid. R/W Float 0
percent_solids_of_material 4003 Density of material Density of Matl -The density of the solid material in the slurry. R/W Float 0
adapt_damp_status 4005 Adapt Damp Status Adapt Damp Status -Control to activate adaptive damping. R/W Enum 0
adapt_damp_value 4006 Adapt Damp Value Adapt Damp Value -The damping time used when the adaptive damping is active. R/W Float 0
damping_threshold 4007 Damping Threshold Damping Threshold -Percent deviation from last value where the adaptive damping becomes active. R/W Float 0
process_description 4009 Process desc Process desc -User entered description of process. R/W PackedAscii 0
temp_comp_status 4011 Temp Comp Status Temp Comp Status -This option turns the temperature compensation on and off. R/W Enum 0
temp_comp_ref_temp 4012 Ref Temp R/W Float 0
temp_comp_expan_coef 4013 Expansion Coef R Float 0
rho1 4015 RHO1 Rho1 -The density of the process at the first temperature. R/W Float 0
rho2 4016 RHO2 Rho2 -The density of the process at the second temmperature. R/W Float 0
temp1 4017 Temp1 Temp1 -The temperature at which the first density value is recorded. R/W Float 0
temp2 4018 Temp2 Temp2 -The temperature at which the second density value is recorded. R/W Float 0
ext_input_units 4020 Unit W Enum 0
ext_input_zero 4021 Zero Value W Float 0
input_span_trim 4023 Span value W Float 0
last_ref_date 4027 Last ref Last ref -The date on which the last reference was taken on the device. R HartDate 0
last_ref_time_hour 4028 Ref hr R Integer 0
last_ref_time_minute 4029 Ref min R Integer 0
last_ref 402A Counts R Float 0
ref_duration 402C Ref duration R Float 0
ref_sample_control_code 402E Ref sample cntrl code R/W Enum 0
cal_point_number 4030 Cal Point Number R/W Index 4096
cal_units 4032 Calib pt unit R/W Integer 0
cal_density_1 4033 #1DENSITY #1DENSITY--The density value for the first calibration point. This point is always used for the calibration curve. R/W Float 0
cal_signal_1 4034 #1SIGNAL #1SIGNAL--The signal value for the first calibration point. This point is always used for the calibration curve. R/W Float 0
cal_density_2 4039 #2DENSITY #2DENSITY--The density value for the second calibration point. This point is always used for the calibration curve. R/W Float 0
cal_signal_2 403A #2SIGNAL #2SIGNAL--The signal value for the second calibration point. This point is always used for the calibration curve. R/W Float 0
cal_density_3 403C #3DENSITY #3DENSITY--The density value for the third calibration point. If this calibration point is not used, the density should be set to zero. R/W Float 0
cal_signal_3 403D #3SIGNAL #3SIGNAL--The signal value for the third calibration point. This point is not used if the density for point three is zero. R/W Float 0
cal_density_4 403F #4DENSITY #4DENSITY--The density value for the fourth calibration point. If this calibration point is not used, the density should be set to zero. R/W Float 0
cal_signal_4 4040 #4SIGNAL #4SIGNAL--The signal value for the fourth calibration point. This point is not used if the density for point four is zero. R/W Float 0
cal_density_5 4042 #5DENSITY #5DENSITY--The density value for the fifth calibration point. If this calibration point is not used, the density should be set to zero. R/W Float 0
cal_signal_5 4043 #5SIGNAL #5SIGNAL--The signal value for the fifth calibration point. This point is not used if the density for point five is zero. R/W Float 0
cal_density_6 4045 #6DENSITY #6DENSITY--The density value for the sixth calibration point. If this calibration point is not used, the density should be set to zero. R/W Float 0
cal_signal_6 4046 #6SIGNAL #6SIGNAL--The signal value for the sixth calibration point. This point is not used if the density for point six is zero. R/W Float 0
sample 404B Sample R Float 0
sample_duration 404C Samp Duration Samp Duration--The time of the sample measurement. The maximum value is 600 seconds. R/W Float 0
dens_offset_units 404F Unit R/W Enum 0
dens_offset 4050 Dens Offset Density Offset--A value supplied by the user and added to the density value measured. R/W Float 0
temp_input_type 4052 Temp Sensor Type Temp Comp Input Sensor Type -The type of sensor used to measure temperature. R/W Enum 0
temp_input_units 4053 Units Temp Comp Units -The units associated with the device used for temperature compensation. R/W Enum 0
ext_input_4ma_point 4054 Zero Point Value Zero Point Value -The zero range point for the temperature transmitter. R/W Float 0
ext_input_20ma_point 4055 Span Value Span Value -The high range point for the temperature transmitter. R/W Float 0
last_cal_locat 4026 Last setup locatn R/W Enum 0
ref_material 4056 Ref matl Ref Material -The material selected for the next reference. R/W Enum 0
gamma_source 4057 Source typ Source Type -The type of source contained in the source housing. R/W Enum 0
xmtr_date 405D Date R/W HartDate 0
xmtr_time_hrs 4061 Time-Hrs R/W Unsigned 0