Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
cal_density_1 | 4033 | #1DENSITY | #1DENSITY--The density value for the first calibration point. This point is always used for the calibration curve. | R/W | Float | 0 |
cal_signal_1 | 4034 | #1SIGNAL | #1SIGNAL--The signal value for the first calibration point. This point is always used for the calibration curve. | R/W | Float | 0 |
cal_density_2 | 4039 | #2DENSITY | #2DENSITY--The density value for the second calibration point. This point is always used for the calibration curve. | R/W | Float | 0 |
cal_signal_2 | 403A | #2SIGNAL | #2SIGNAL--The signal value for the second calibration point. This point is always used for the calibration curve. | R/W | Float | 0 |
cal_density_3 | 403C | #3DENSITY | #3DENSITY--The density value for the third calibration point. If this calibration point is not used, the density should be set to zero. | R/W | Float | 0 |
cal_signal_3 | 403D | #3SIGNAL | #3SIGNAL--The signal value for the third calibration point. This point is not used if the density for point three is zero. | R/W | Float | 0 |
cal_density_4 | 403F | #4DENSITY | #4DENSITY--The density value for the fourth calibration point. If this calibration point is not used, the density should be set to zero. | R/W | Float | 0 |
cal_signal_4 | 4040 | #4SIGNAL | #4SIGNAL--The signal value for the fourth calibration point. This point is not used if the density for point four is zero. | R/W | Float | 0 |
cal_density_5 | 4042 | #5DENSITY | #5DENSITY--The density value for the fifth calibration point. If this calibration point is not used, the density should be set to zero. | R/W | Float | 0 |
cal_signal_5 | 4043 | #5SIGNAL | #5SIGNAL--The signal value for the fifth calibration point. This point is not used if the density for point five is zero. | R/W | Float | 0 |
cal_density_6 | 4045 | #6DENSITY | #6DENSITY--The density value for the sixth calibration point. If this calibration point is not used, the density should be set to zero. | R/W | Float | 0 |
cal_signal_6 | 4046 | #6SIGNAL | #6SIGNAL--The signal value for the sixth calibration point. This point is not used if the density for point six is zero. | R/W | Float | 0 |
sample | 404B | Sample | R | Float | 0 | |
sample_duration | 404C | Samp Duration | Samp Duration--The time of the sample measurement. The maximum value is 600 seconds. | R/W | Float | 0 |
dens_offset_units | 404F | Unit | R/W | Enum | 0 | |
dens_offset | 4050 | Dens Offset | Density Offset--A value supplied by the user and added to the density value measured. | R/W | Float | 0 |
temp_input_type | 4052 | Temp Sensor Type | Temp Comp Input Sensor Type -The type of sensor used to measure temperature. | R/W | Enum | 0 |
temp_input_units | 4053 | Units | Temp Comp Units -The units associated with the device used for temperature compensation. | R/W | Enum | 0 |
ext_input_4ma_point | 4054 | Zero Point Value | Zero Point Value -The zero range point for the temperature transmitter. | R/W | Float | 0 |
ext_input_20ma_point | 4055 | Span Value | Span Value -The high range point for the temperature transmitter. | R/W | Float | 0 |
last_cal_locat | 4026 | Last setup locatn | R/W | Enum | 0 | |
ref_material | 4056 | Ref matl | Ref Material -The material selected for the next reference. | R/W | Enum | 0 |
gamma_source | 4057 | Source typ | Source Type -The type of source contained in the source housing. | R/W | Enum | 0 |
xmtr_date | 405D | Date | R/W | HartDate | 0 | |
xmtr_time_hrs | 4061 | Time-Hrs | R/W | Unsigned | 0 | |
Name | ID | Label | Description | Type | Access | Class |