Name ID Label Description Type Access Class
lstLinearizationDistance 4077 Limit Status Limit Status 'LS' R/W Enum 10
fstLinearizationDistance 4078 Family Status Family Status 'FS' R BitEnum 10
utpLinearizationDistance 4079 Update Time Update Time Period 'UTP'. Indicates the maximum period between updates of the process variable. R Time 8
simulateLinearizationDistance 407A Set Simulation Desired setting of the process variable simulation. If enabled, the process variable will be simulated and won't show the actual process value. W Enum 2048
propertiesLinearizationDistance 407B Properties Properties, indicate e.g. the simulation state. R BitEnum 10
dfoUllage 407E Format Ullage Display format for Ullage. Local for HART applications, no correlation with device's local display. R/W Enum 4096
dvlUllage 407D Ullage By applying a suitable conversion table, the distance to the medium can be converted into its volume. It is only available if the conversion table is configured for volume conversion. R/W Float 10
uslUllage 407F Upper Sensor Limit Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
lslUllage 4080 Lower Sensor Limit Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 8
mspUllage 4081 Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
dfaUllage 4082 Family Device Variable Family R Enum 8
dqaUllage 4083 Data Quality Process Data Quality 'PDQ' R/W Enum 10
lstUllage 4084 Limit Status Limit Status 'LS' R/W Enum 10
fstUllage 4085 Family Status Family Status 'FS' R BitEnum 10
utpUllage 4086 Update Time Update Time Period 'UTP'. Indicates the maximum period between updates of the process variable. R Time 8
simulateUllage 4087 Set Simulation Desired setting of the process variable simulation. If enabled, the process variable will be simulated and won't show the actual process value. W Enum 2048
propertiesUllage 4088 Properties Properties, indicate e.g. the simulation state. R BitEnum 10
dfoUllageMass 408B Format Ullage Mass Display format for Ullage Mass. Local for HART applications, no correlation with device's local display. R/W Enum 4096
dvlUllageMass 408A Ullage Mass By applying a suitable conversion table, the distance to the medium can be converted into its mass. It is only available if the conversion table is configured for mass conversion. R/W Float 10
uslUllageMass 408C Upper Sensor Limit Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
lslUllageMass 408D Lower Sensor Limit Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 8
mspUllageMass 408E Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8
dfaUllageMass 408F Family Device Variable Family R Enum 8
dqaUllageMass 4090 Data Quality Process Data Quality 'PDQ' R/W Enum 10
lstUllageMass 4091 Limit Status Limit Status 'LS' R/W Enum 10
fstUllageMass 4092 Family Status Family Status 'FS' R BitEnum 10
utpUllageMass 4093 Update Time Update Time Period 'UTP'. Indicates the maximum period between updates of the process variable. R Time 8
simulateUllageMass 4094 Set Simulation Desired setting of the process variable simulation. If enabled, the process variable will be simulated and won't show the actual process value. W Enum 2048
propertiesUllageMass 4095 Properties Properties, indicate e.g. the simulation state. R BitEnum 10
eSelectionAnalogOutput 4097 eSelectionAnalogOutput R/W Enum 4096
eSelectionCurrentOutput 4098 eSelectionCurrentOutput R/W Enum 4096
PVloopUnits 2EE0 AO unit R Enum 64
PVloopDamping 2EE1 Added damp Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. R Float 64
PVloopCurrentUpperEndPoint 2EE2 100% Current Output current of the 100% signal R/W Float 64
PVloopCurrentLowerEndPoint 2EE3 0% Current Output current of the 0% signal R/W Float 64
PVloopCurrentUpperLimit 2EE4 Upper Ext. Range Configure the upper extended range in mA (Fct. C2.1.4) R/W Float 64
PVloopCurrentLowerLimit 2EE5 Lower Ext. Range Configure the lower extended range in mA (Fct. C2.1.4) R/W Float 64
SVloopCurrent 2EE8 SV output value SV output value R/W Float 66
SVloopUnits 2EE9 AO unit R Enum 64
SVloopDamping 2EEC Added damp Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. R Float 64
SVloopCurrentUpperEndPoint 2EED AO hi end pt Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions R Float 64
SVloopCurrentLowerEndPoint 2EEE AO lo end pt Analog Output Lower Endpoint Value- Defines the lower endpoint, of the respective Analog Output, for normal operating conditions R Float 64
SVloopCurrentUpperLimit 2EEF Upper Limit Value The maximum value of the analog signal. R Float 64
SVloopCurrentLowerLimit 2EF0 Lower Limit Value The minimum value of the analog signal. R Float 64
SVpercentRange 2EF1 SV % range Percent of range of the HART Secondary Variable (SV); tracks the associated measured value with respect to the Lower Range Value and Upper Range Value. R Float 34
SVupperRange_value 2EF3 URV Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
SVlowerRange_value 2EF4 LRV Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
TVloopCurrent 2EF7 TV output value TV output value R/W Float 66
TVloopUnits 2EF8 AO unit R Enum 64
TVloopDamping 2EFB Added damp Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. R Float 64