Loading…
Name ID Label Description Type Access Class
utpReflection 4041 Update Time Update Time Period 'UTP'. Indicates the maximum period between updates of the process variable. R Time 8
simulateReflection 4042 Set Simulation Desired setting of the process variable simulation. If enabled, the process variable will be simulated and won't show the actual process value. W Enum 2048
propertiesReflection 4043 Properties Properties, indicate e.g. the simulation state. R BitEnum 10
dfoLinearizationLevel 4046 Format Level Linearization Display format for Level Linearization. Local for HART applications, no correlation with device's local display. R/W Enum 4096
dvlLinearizationLevel 4045 Level Linearization The linearized level value. It is only available if the conversion table is configured for level linearization. R/W Float 10
uslLinearizationLevel 4047 Upper Sensor Limit Значение верхнего предела сенсора - определяет максимальное используемое значение для значения верхнего предела диапазона R Float 8
lslLinearizationLevel 4048 Lower Sensor Limit Значение нижнего предела сенсора - определяет минимальное используемое значение для значения нижнего предела диапазона R Float 8
mspLinearizationLevel 4049 Minimum Span Значение минимального диапазона - определяет наименьшую допустимую разницу между значениями верхнего и нижнего пределов диапазона R Float 8
dfaLinearizationLevel 404A Family Device Variable Family R Enum 8
dqaLinearizationLevel 404B Data Quality Process Data Quality 'PDQ' R/W Enum 10
lstLinearizationLevel 404C Limit Status Limit Status 'LS' R/W Enum 10
fstLinearizationLevel 404D Family Status Family Status 'FS' R BitEnum 10
utpLinearizationLevel 404E Update Time Update Time Period 'UTP'. Indicates the maximum period between updates of the process variable. R Time 8
simulateLinearizationLevel 404F Set Simulation Desired setting of the process variable simulation. If enabled, the process variable will be simulated and won't show the actual process value. W Enum 2048
propertiesLinearizationLevel 4050 Properties Properties, indicate e.g. the simulation state. R BitEnum 10
dunVolume 4052 Unit Volume Unit for Volume. R/W Enum 8
dfoVolume 4054 Format Volume Display format for Volume. Local for HART applications, no correlation with device's local display. R/W Enum 4096
dvlVolume 4053 Volume By applying a suitable conversion table, the level of the medium can be converted into its volume. It is only available if the conversion table is configured for volume conversion. R/W Float 10
uslVolume 4055 Upper Sensor Limit Значение верхнего предела сенсора - определяет максимальное используемое значение для значения верхнего предела диапазона R Float 8
lslVolume 4056 Lower Sensor Limit Значение нижнего предела сенсора - определяет минимальное используемое значение для значения нижнего предела диапазона R Float 8
mspVolume 4057 Minimum Span Значение минимального диапазона - определяет наименьшую допустимую разницу между значениями верхнего и нижнего пределов диапазона R Float 8
clsVolume 4058 Unit Class Volume Device Variable Class. Defines also the set of selectable physical units. R Enum 8
dfaVolume 4059 Family Device Variable Family R Enum 8
dqaVolume 405A Data Quality Process Data Quality 'PDQ' R/W Enum 10
lstVolume 405B Limit Status Limit Status 'LS' R/W Enum 10
Name ID Label Description Type Access Class