Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
rmt_flow_flange_type | 1FAB | Flange type | Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor. | R/W | Enum | 2048 |
rmt_flow_flange_material | 1FAC | Flnge matl | Flange Material- Construction material described by the variable. flange_type | R/W | Enum | 2048 |
rmt_flow_meter_installation | 1FAA | Meter type | Meter Installation- Defines whether there is a meter installed or not and possibly what information the meter will display. | R/W | Enum | 256 |
liner_material | 1F41 | Liner matl | Liner Material- Material of construction of the liner. | R/W | Enum | 2048 |
electrode_type | 1F42 | Electrode typ | Electrode Type- Physical shape of the electrode. | R/W | Enum | 2048 |
electrode_material | 1F43 | Electrode matl | Electrode Material- Material of construction of the electrode. | R/W | Enum | 2048 |
flow_tube_tag | 1F44 | Flo tube tag | Flow Tube Tag- Text that is associated with the flow tube. | R/W | PackedAscii | 2048 |
special_base_vol_unit | 1F47 | Base vol unit | Process Variable Base Unit- Special units reference to create a custom unit. Process variable special units = variable special_process_variable_unit_conv_number * (variable special_process_variable_base_unit / variable special_process_varaible_base_time_unit). | R/W | Enum | 32 |
special_base_time_units | 1F48 | Base time unit | Base Time Unit- Special time reference to create a custom unit. Process variable special units = variable special_process_variable_unit_conv_number * (variable special_process_variable_base_unit / variable special_process_varaible_base_time_unit). | R/W | Enum | 32 |
special_unit_conv_number | 1F49 | conversion number | Special Unit Conversion Number- Arithmetic factor used in converting standard units to special units. | R/W | Float | 32 |
special_vol_unit | 1F4A | Vol unit | Special Volume Unit- Text string used to designate special volumetric unit. | R/W | ASCII | 32 |
special_flow_rate_unit | 1F4B | Flo rate unit | Special Flow Rate Unit- Text string used to designate special flow rate units. | R/W | ASCII | 32 |
coil_drive_frequency | 1F4D | Coil driv freq | Coil Drive Frequency- Frequency that the coils operate at. | R/W | Enum | 8 |
pulse_output_units | 1F4E | FO1 Puls out unit | Pulse Output Unit- Engineering units that the frequency andtotalizer outputs will be displayed with. | R/W | Enum | 32 |
gross_total_units | 1FAD | ?? | R/W | Enum | 0 | |
pulse_scaling | 1F4F | Puls scaling | Pulse Scaling Factor- Magnitude of process variable per pulse. | R/W | Float | 512 |
pulse_width_value | 1F50 | Puls width | Pulse Width- Width of the frequency output pulse on frequency output number 'X'. | R/W | Integer | 512 |
low_flow_cutoff | 1F51 | Lo flo cutoff | Low Flow Cutoff- Set point that determines when the process variable will indicate 0 rather than some nominally small value. | R/W | Float | 64 |
flow_tube_size | 1F52 | Line size | Line Size- Nominal inside diameter of the pipe adjacent to the sensor. | R/W | Integer | 8 |
signal_processing_status | 1F53 | Status | Signal Processing Status- Turns signal processing on or off. Signal processing is an averaging algorithm used to prevent noisy input signals from affecting the output. | R/W | Enum | 32 |
signal_processing_samples | 1F54 | Samples | Signal Processing Number of Samples- Number of input samples to be averaged. | R/W | Integer | 32 |
signal_processing_percent | 1F55 | % rate | Signal Processing Percent- This number sets up a limiting band around the average value to determine when an input sample is noisy. Inputs samples that are outside of this band are not included in the averaging algorithm. | R/W | Integer | 32 |
signal_processing_limit | 1F56 | Time limit | Signal Processing Limit- The limit factor is used to catch step changes in flow. If the input signals are either above, or below the average value for more than the limit time the output will be driven to the new level, and averaging will start over at this point. | R/W | Integer | 32 |
flow_tube_calibration_number | 1F58 | Calib num | Flow Tube Calibration Number- This number is uniquely associated with the flow tube, and is used to compensate for gain and zero shifts associated with the specific tube. The calibration number is calculated at the factory and is stamped on the flow tube. | R/W | ASCII | 8 |
total_control | 1F67 | Totlizer cntrl | Totalizer Control Code- Controls the operation of all available totalizers. | W | Enum | 16 |