名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
rmt_flow_flange_type | 1FAB | 法兰类型 | Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor. | 读/写 | 枚举 | 2048 |
rmt_flow_flange_material | 1FAC | 法兰材料 | Flange Material- Construction material described by the variable. flange_type | 读/写 | 枚举 | 2048 |
rmt_flow_meter_installation | 1FAA | 仪表类型 | Meter Installation- Defines whether there is a meter installed or not and possibly what information the meter will display. | 读/写 | 枚举 | 256 |
liner_material | 1F41 | 隔离材料 | Liner Material- Material of construction of the liner. | 读/写 | 枚举 | 2048 |
electrode_type | 1F42 | 电极类型 | Electrode Type- Physical shape of the electrode. | 读/写 | 枚举 | 2048 |
electrode_material | 1F43 | 电极材料 | Electrode Material- Material of construction of the electrode. | 读/写 | 枚举 | 2048 |
flow_tube_tag | 1F44 | 流量管位号 | Flow Tube Tag- Text that is associated with the flow tube. | 读/写 | 压缩文本 | 2048 |
special_base_vol_unit | 1F47 | 基本体积单位 | Process Variable Base Unit- Special units reference to create a custom unit. Process variable special units = variable special_process_variable_unit_conv_number * (variable special_process_variable_base_unit / variable special_process_varaible_base_time_unit). | 读/写 | 枚举 | 32 |
special_base_time_units | 1F48 | 基本时间单位 | Base Time Unit- Special time reference to create a custom unit. Process variable special units = variable special_process_variable_unit_conv_number * (variable special_process_variable_base_unit / variable special_process_varaible_base_time_unit). | 读/写 | 枚举 | 32 |
special_unit_conv_number | 1F49 | conversion number | Special Unit Conversion Number- Arithmetic factor used in converting standard units to special units. | 读/写 | 浮点 | 32 |
special_vol_unit | 1F4A | 体积单位 | Special Volume Unit- Text string used to designate special volumetric unit. | 读/写 | ASCII | 32 |
special_flow_rate_unit | 1F4B | 流量速率单位 | Special Flow Rate Unit- Text string used to designate special flow rate units. | 读/写 | ASCII | 32 |
coil_drive_frequency | 1F4D | 线圈驱动器频率 | Coil Drive Frequency- Frequency that the coils operate at. | 读/写 | 枚举 | 8 |
pulse_output_units | 1F4E | FO1脉冲输出单位 | Pulse Output Unit- Engineering units that the frequency andtotalizer outputs will be displayed with. | 读/写 | 枚举 | 32 |
gross_total_units | 1FAD | ?? | 读/写 | 枚举 | 0 | |
pulse_scaling | 1F4F | 脉冲缩放 | Pulse Scaling Factor- Magnitude of process variable per pulse. | 读/写 | 浮点 | 512 |
pulse_width_value | 1F50 | 脉冲宽度 | Pulse Width- Width of the frequency output pulse on frequency output number 'X'. | 读/写 | 整型 | 512 |
low_flow_cutoff | 1F51 | 小流量切除 | Low Flow Cutoff- Set point that determines when the process variable will indicate 0 rather than some nominally small value. | 读/写 | 浮点 | 64 |
flow_tube_size | 1F52 | Line size | Line Size- Nominal inside diameter of the pipe adjacent to the sensor. | 读/写 | 整型 | 8 |
signal_processing_status | 1F53 | 状态 | Signal Processing Status- Turns signal processing on or off. Signal processing is an averaging algorithm used to prevent noisy input signals from affecting the output. | 读/写 | 枚举 | 32 |
signal_processing_samples | 1F54 | 样本 | Signal Processing Number of Samples- Number of input samples to be averaged. | 读/写 | 整型 | 32 |
signal_processing_percent | 1F55 | % 比率 | Signal Processing Percent- This number sets up a limiting band around the average value to determine when an input sample is noisy. Inputs samples that are outside of this band are not included in the averaging algorithm. | 读/写 | 整型 | 32 |
signal_processing_limit | 1F56 | 时间限制 | Signal Processing Limit- The limit factor is used to catch step changes in flow. If the input signals are either above, or below the average value for more than the limit time the output will be driven to the new level, and averaging will start over at this point. | 读/写 | 整型 | 32 |
flow_tube_calibration_number | 1F58 | 标定数 | Flow Tube Calibration Number- This number is uniquely associated with the flow tube, and is used to compensate for gain and zero shifts associated with the specific tube. The calibration number is calculated at the factory and is stamped on the flow tube. | 读/写 | ASCII | 8 |
total_control | 1F67 | 累加器控制 | Totalizer Control Code- Controls the operation of all available totalizers. | 写 | 枚举 | 16 |
auxiliary_output | 1F6A | 辅助输出 | Auxiliary output- Discrete switch closure output that signals either reverse or 0 flow through the flow tube. | 读/写 | 枚举 | 1024 |
operate_mode | 1F6D | 操作模式 | Noise Supression- Level or mode of noise supression. | 读/写 | 枚举 | 8 |
flow_units | 1F7B | 主变量单位 | 现场设备变量单位——使用数值表示、最小范围、范围上限、范围下限、传感器上限和传感器下限显示的工程单位。 | 读/写 | 枚举 | 32 |
flow_value | 1F7C | 主变量 | 现场设备变量值——在没有用户干扰的条件下,根据时间改变大小的数值。 | 读/写 | 浮点 | 34 |
flow_analog_value | 1F7D | AO1 | 模拟量输出值——在正常工作模式下跟踪数值表示的数值。 | 读/写 | 浮点 | 66 |
flow_percent_range | 1F7E | 主变量 % 范围 | % 范围——跟踪有关下限值和上限值所定义范围的数值表示的变量,该变量的单位始终为百分数。 | 读/写 | 浮点 | 34 |
flow_upper_sensor_limit | 1F7F | 主变量传感器量程上限 | 传感器上限值——定义上限值的最大可用数值。 | 读/写 | 浮点 | 8 |
flow_lower_sensor_limit | 1F80 | 主变量传感器量程下限 | 传感器下限值——定义上限值的最小可用数值。 | 读/写 | 浮点 | 8 |
flow_minimum_span | 1F81 | 主变量最小范围 | 最小范围值——定义上限值和下限值之间允许的最小差。 | 读/写 | 浮点 | 32 |
flow_sensor_serial_number | 1F82 | 主变量传感器序列号 | 传感器序列号——识别数值表示或现场设备变量来源的传感器。 | 读/写 | 无符号 | 2048 |
flow_alarm_select | 1F83 | 模拟量输出报警类型 | 模拟量输出报警类型——定义当现场设备检测到模拟量输出可能未跟踪关联现场设备变量时模拟量输出响应的方式。注意——数值表示可能不确定。 | 读 | 枚举 | 64 |
transfer_function | 1F84 | 转换功能 | 传送功能——定义由现场设备变量应用至模拟量输出和百分比范围的传送功能。传送功能不影响数值表示。 | 读 | 枚举 | 64 |
flow_range_units | 1F88 | 主变量范围单位 | 范围单位——使用上限值和下限值表示的工程单位。 | 读/写 | 枚举 | 32 |
flow_upper_range_value | 1F85 | 主变量实际量程上限 | 上限值——定义模拟值和范围100%点开始的操作端点。此外,上限值还定义与模拟量值关联的报警和与数值表示关联的报警开始的操作端点。 | 读/写 | 浮点 | 32 |
flow_lower_range_value | 1F86 | 主变量实际量程下限 | 下限值——定义模拟值和范围0%点开始的操作端点。此外,下限值还定义与模拟量值关联的报警和与数值表示关联的报警开始的操作端点。 | 读/写 | 浮点 | 32 |
flow_damping_value | 1F87 | 主变量阻尼 | 阻尼值——同时应用至各自模拟量输出的数值表示和模拟值的阻尼时间常数。该变量的单位始终为秒钟。 | 读/写 | 浮点 | 32 |
pulse_output_value | 1F73 | Puls outp | Pulse Output Value- scaled frequency output from 0-1000 Hz, linear with input. | 读 | 浮点 | 514 |
pulse_output_test | 1F66 | Puls outp test | Pulse Output Test Value- Scaled frequency output from 0-1000 Hz, linear with input. | 读/写 | 整型 | 4096 |
gross_total_value | 1F89 | 测量总量 | Gross Total Value- Non-resettable totalizer value. Counts frequency output pulses while total control is turned on. This value will be reset to 0 when the pulse scaling, line size, or units are changed. | 读 | 浮点 | 18 |
net_total_value | 1F8A | 测量净值 | Net Total Value- Resettable totalizer value. Counts frequency output pulses while total control is turned on. | 读 | 浮点 | 18 |
reverse_total_value | 1F8B | 测量反向总量 | Reverse Total Value- Non-resettable totalizer value. Counts frequency output pulses while total control is turned on and flow is in the reverse direction. This value will be reset to 0 when the pulse scaling, line size, or units are changed. | 读 | 浮点 | 18 |
unique_device_type_code | 07ED | 读/写 | 枚举 | 128 | ||
rosemount_model_code | 07F5 | 读/写 | 枚举 | 2048 | ||
rosemount_analytical_model_code | 07F6 | 读/写 | 枚举 | 2048 | ||
kayray_model_code | 07F7 | 读/写 | 枚举 | 2048 | ||
名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |