名称 ID 标签 描述 类型 访问 分类
rmt_flow_flange_type 1FAB 法兰类型 Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor. 读/写 枚举 2048
rmt_flow_flange_material 1FAC 法兰材料 Flange Material- Construction material described by the variable. flange_type 读/写 枚举 2048
rmt_flow_meter_installation 1FAA 仪表类型 Meter Installation- Defines whether there is a meter installed or not and possibly what information the meter will display. 读/写 枚举 256
liner_material 1F41 隔离材料 Liner Material- Material of construction of the liner. 读/写 枚举 2048
electrode_type 1F42 电极类型 Electrode Type- Physical shape of the electrode. 读/写 枚举 2048
electrode_material 1F43 电极材料 Electrode Material- Material of construction of the electrode. 读/写 枚举 2048
flow_tube_tag 1F44 流量管位号 Flow Tube Tag- Text that is associated with the flow tube. 读/写 压缩文本 2048
special_base_vol_unit 1F47 基本体积单位 Process Variable Base Unit- Special units reference to create a custom unit. Process variable special units = variable special_process_variable_unit_conv_number * (variable special_process_variable_base_unit / variable special_process_varaible_base_time_unit). 读/写 枚举 32
special_base_time_units 1F48 基本时间单位 Base Time Unit- Special time reference to create a custom unit. Process variable special units = variable special_process_variable_unit_conv_number * (variable special_process_variable_base_unit / variable special_process_varaible_base_time_unit). 读/写 枚举 32
special_unit_conv_number 1F49 conversion number Special Unit Conversion Number- Arithmetic factor used in converting standard units to special units. 读/写 浮点 32
special_vol_unit 1F4A 体积单位 Special Volume Unit- Text string used to designate special volumetric unit. 读/写 ASCII 32
special_flow_rate_unit 1F4B 流量速率单位 Special Flow Rate Unit- Text string used to designate special flow rate units. 读/写 ASCII 32
coil_drive_frequency 1F4D 线圈驱动器频率 Coil Drive Frequency- Frequency that the coils operate at. 读/写 枚举 8
pulse_output_units 1F4E FO1脉冲输出单位 Pulse Output Unit- Engineering units that the frequency andtotalizer outputs will be displayed with. 读/写 枚举 32
gross_total_units 1FAD ?? 读/写 枚举 0
pulse_scaling 1F4F 脉冲缩放 Pulse Scaling Factor- Magnitude of process variable per pulse. 读/写 浮点 512
pulse_width_value 1F50 脉冲宽度 Pulse Width- Width of the frequency output pulse on frequency output number 'X'. 读/写 整型 512
low_flow_cutoff 1F51 小流量切除 Low Flow Cutoff- Set point that determines when the process variable will indicate 0 rather than some nominally small value. 读/写 浮点 64
flow_tube_size 1F52 Line size Line Size- Nominal inside diameter of the pipe adjacent to the sensor. 读/写 整型 8
signal_processing_status 1F53 状态 Signal Processing Status- Turns signal processing on or off. Signal processing is an averaging algorithm used to prevent noisy input signals from affecting the output. 读/写 枚举 32
signal_processing_samples 1F54 样本 Signal Processing Number of Samples- Number of input samples to be averaged. 读/写 整型 32
signal_processing_percent 1F55 % 比率 Signal Processing Percent- This number sets up a limiting band around the average value to determine when an input sample is noisy. Inputs samples that are outside of this band are not included in the averaging algorithm. 读/写 整型 32
signal_processing_limit 1F56 时间限制 Signal Processing Limit- The limit factor is used to catch step changes in flow. If the input signals are either above, or below the average value for more than the limit time the output will be driven to the new level, and averaging will start over at this point. 读/写 整型 32
flow_tube_calibration_number 1F58 标定数 Flow Tube Calibration Number- This number is uniquely associated with the flow tube, and is used to compensate for gain and zero shifts associated with the specific tube. The calibration number is calculated at the factory and is stamped on the flow tube. 读/写 ASCII 8
total_control 1F67 累加器控制 Totalizer Control Code- Controls the operation of all available totalizers. 枚举 16
auxiliary_output 1F6A 辅助输出 Auxiliary output- Discrete switch closure output that signals either reverse or 0 flow through the flow tube. 读/写 枚举 1024
operate_mode 1F6D 操作模式 Noise Supression- Level or mode of noise supression. 读/写 枚举 8
flow_units 1F7B 主变量单位 现场设备变量单位——使用数值表示、最小范围、范围上限、范围下限、传感器上限和传感器下限显示的工程单位。 读/写 枚举 32
flow_value 1F7C 主变量 现场设备变量值——在没有用户干扰的条件下,根据时间改变大小的数值。 读/写 浮点 34
flow_analog_value 1F7D AO1 模拟量输出值——在正常工作模式下跟踪数值表示的数值。 读/写 浮点 66
flow_percent_range 1F7E 主变量 % 范围 % 范围——跟踪有关下限值和上限值所定义范围的数值表示的变量,该变量的单位始终为百分数。 读/写 浮点 34
flow_upper_sensor_limit 1F7F 主变量传感器量程上限 传感器上限值——定义上限值的最大可用数值。 读/写 浮点 8
flow_lower_sensor_limit 1F80 主变量传感器量程下限 传感器下限值——定义上限值的最小可用数值。 读/写 浮点 8
flow_minimum_span 1F81 主变量最小范围 最小范围值——定义上限值和下限值之间允许的最小差。 读/写 浮点 32
flow_sensor_serial_number 1F82 主变量传感器序列号 传感器序列号——识别数值表示或现场设备变量来源的传感器。 读/写 无符号 2048
flow_alarm_select 1F83 模拟量输出报警类型 模拟量输出报警类型——定义当现场设备检测到模拟量输出可能未跟踪关联现场设备变量时模拟量输出响应的方式。注意——数值表示可能不确定。 枚举 64
transfer_function 1F84 转换功能 传送功能——定义由现场设备变量应用至模拟量输出和百分比范围的传送功能。传送功能不影响数值表示。 枚举 64
flow_range_units 1F88 主变量范围单位 范围单位——使用上限值和下限值表示的工程单位。 读/写 枚举 32
flow_upper_range_value 1F85 主变量实际量程上限 上限值——定义模拟值和范围100%点开始的操作端点。此外,上限值还定义与模拟量值关联的报警和与数值表示关联的报警开始的操作端点。 读/写 浮点 32
flow_lower_range_value 1F86 主变量实际量程下限 下限值——定义模拟值和范围0%点开始的操作端点。此外,下限值还定义与模拟量值关联的报警和与数值表示关联的报警开始的操作端点。 读/写 浮点 32
flow_damping_value 1F87 主变量阻尼 阻尼值——同时应用至各自模拟量输出的数值表示和模拟值的阻尼时间常数。该变量的单位始终为秒钟。 读/写 浮点 32
pulse_output_value 1F73 Puls outp Pulse Output Value- scaled frequency output from 0-1000 Hz, linear with input. 浮点 514
pulse_output_test 1F66 Puls outp test Pulse Output Test Value- Scaled frequency output from 0-1000 Hz, linear with input. 读/写 整型 4096
gross_total_value 1F89 测量总量 Gross Total Value- Non-resettable totalizer value. Counts frequency output pulses while total control is turned on. This value will be reset to 0 when the pulse scaling, line size, or units are changed. 浮点 18
net_total_value 1F8A 测量净值 Net Total Value- Resettable totalizer value. Counts frequency output pulses while total control is turned on. 浮点 18
reverse_total_value 1F8B 测量反向总量 Reverse Total Value- Non-resettable totalizer value. Counts frequency output pulses while total control is turned on and flow is in the reverse direction. This value will be reset to 0 when the pulse scaling, line size, or units are changed. 浮点 18
unique_device_type_code 07ED 读/写 枚举 128
rosemount_model_code 07F5 读/写 枚举 2048
rosemount_analytical_model_code 07F6 读/写 枚举 2048
kayray_model_code 07F7 读/写 枚举 2048
名称 ID 标签 描述 类型 访问 分类