名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
rmt_flow_flange_type | 1FAB | 法兰类型 | Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor. | 读/写 | 枚举 | 2048 |
rmt_flow_flange_material | 1FAC | 法兰材料 | Flange Material- Construction material described by the variable. flange_type | 读/写 | 枚举 | 2048 |
rmt_flow_meter_installation | 1FAA | 仪表类型 | Meter Installation- Defines whether there is a meter installed or not and possibly what information the meter will display. | 读/写 | 枚举 | 256 |
liner_material | 1F41 | 隔离材料 | Liner Material- Material of construction of the liner. | 读/写 | 枚举 | 2048 |
electrode_type | 1F42 | 电极类型 | Electrode Type- Physical shape of the electrode. | 读/写 | 枚举 | 2048 |
electrode_material | 1F43 | 电极材料 | Electrode Material- Material of construction of the electrode. | 读/写 | 枚举 | 2048 |
flow_tube_tag | 1F44 | 流量管位号 | Flow Tube Tag- Text that is associated with the flow tube. | 读/写 | 压缩文本 | 2048 |
special_base_vol_unit | 1F47 | 基本体积单位 | Process Variable Base Unit- Special units reference to create a custom unit. Process variable special units = variable special_process_variable_unit_conv_number * (variable special_process_variable_base_unit / variable special_process_varaible_base_time_unit). | 读/写 | 枚举 | 32 |
special_base_time_units | 1F48 | 基本时间单位 | Base Time Unit- Special time reference to create a custom unit. Process variable special units = variable special_process_variable_unit_conv_number * (variable special_process_variable_base_unit / variable special_process_varaible_base_time_unit). | 读/写 | 枚举 | 32 |
special_unit_conv_number | 1F49 | conversion number | Special Unit Conversion Number- Arithmetic factor used in converting standard units to special units. | 读/写 | 浮点 | 32 |
special_vol_unit | 1F4A | 体积单位 | Special Volume Unit- Text string used to designate special volumetric unit. | 读/写 | ASCII | 32 |
special_flow_rate_unit | 1F4B | 流量速率单位 | Special Flow Rate Unit- Text string used to designate special flow rate units. | 读/写 | ASCII | 32 |
coil_drive_frequency | 1F4D | 线圈驱动器频率 | Coil Drive Frequency- Frequency that the coils operate at. | 读/写 | 枚举 | 8 |
pulse_output_units | 1F4E | FO1脉冲输出单位 | Pulse Output Unit- Engineering units that the frequency andtotalizer outputs will be displayed with. | 读/写 | 枚举 | 32 |
gross_total_units | 1FAD | ?? | 读/写 | 枚举 | 0 | |
pulse_scaling | 1F4F | 脉冲缩放 | Pulse Scaling Factor- Magnitude of process variable per pulse. | 读/写 | 浮点 | 512 |
pulse_width_value | 1F50 | 脉冲宽度 | Pulse Width- Width of the frequency output pulse on frequency output number 'X'. | 读/写 | 整型 | 512 |
low_flow_cutoff | 1F51 | 小流量切除 | Low Flow Cutoff- Set point that determines when the process variable will indicate 0 rather than some nominally small value. | 读/写 | 浮点 | 64 |
flow_tube_size | 1F52 | Line size | Line Size- Nominal inside diameter of the pipe adjacent to the sensor. | 读/写 | 整型 | 8 |
signal_processing_status | 1F53 | 状态 | Signal Processing Status- Turns signal processing on or off. Signal processing is an averaging algorithm used to prevent noisy input signals from affecting the output. | 读/写 | 枚举 | 32 |
signal_processing_samples | 1F54 | 样本 | Signal Processing Number of Samples- Number of input samples to be averaged. | 读/写 | 整型 | 32 |
signal_processing_percent | 1F55 | % 比率 | Signal Processing Percent- This number sets up a limiting band around the average value to determine when an input sample is noisy. Inputs samples that are outside of this band are not included in the averaging algorithm. | 读/写 | 整型 | 32 |
signal_processing_limit | 1F56 | 时间限制 | Signal Processing Limit- The limit factor is used to catch step changes in flow. If the input signals are either above, or below the average value for more than the limit time the output will be driven to the new level, and averaging will start over at this point. | 读/写 | 整型 | 32 |
flow_tube_calibration_number | 1F58 | 标定数 | Flow Tube Calibration Number- This number is uniquely associated with the flow tube, and is used to compensate for gain and zero shifts associated with the specific tube. The calibration number is calculated at the factory and is stamped on the flow tube. | 读/写 | ASCII | 8 |
total_control | 1F67 | 累加器控制 | Totalizer Control Code- Controls the operation of all available totalizers. | 写 | 枚举 | 16 |