Name ID Label Description Type Access Class
pressure_lower_range_value 1397 Druck Messanfang Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Float 32
pressure_damping_value 1398 Druck Dämpfung Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective Analog Output. The units of this variable are always in seconds. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Float 8
flange_type 139A Flanschtyp Flange Type- Hardware, adjacent to the sensor, that physically connects the process to the sensor. Pressure- Pressure of the process measured with respect to a reference pressure. R/W Enum 2048
o_ring_material 139B O-Ring Werkstoff O Ring Material- Construction material of a seal that exists between the module and flange. R/W Enum 2048
meter_installation 139C Anzeiger Typ Meter Installation- Defines whether there is a meter installed or not and possibly what information the meter will display. R/W Enum 256
remote_seal_type 139D Druckmittler Typ Remote Seal Type- Type of device that is capable of detecting and passing on the process pressure on to the module. This is only unambiguous if 1 remote seal is installed. R/W Enum 2048
module_fill_fluid 139E Füllflüssigkeit Sensor Fill Fluid- Fluid material in the module. R Enum 2048
number_of_remote_seals 139F Anzahl Druckmittler Number of Remote Seals- Physical quantity of the seals for the remote seal that is installed. R/W Enum 2048
unique_device_type_code 07ED R/W Enum 128
rosemount_model_code 07F5 R/W Enum 2048
Name ID Label Description Type Access Class