Name ID Label Description Type Access Class
MOB_false_echo4_distance 40B6 Fourth P087 Fourth Distance - the distance from the sensor face to the fourth false echo. R/W Float 8
MOB_false_echo4_size 40CC Fourth P088 Fourth Size - the size of the fourth false echo R/W Float 8
MOB_clear_false_echo 40D1 Clear False Echoes Clear False Echo - remove the selected false echo from the transmitter's database. W Enum 8
MOB_present_depth 40B7 Present Depth Present Depth - enter the present depth of liquid and the transmitter will automatically set the correct Bottom Reference. W Float 32
MOB_distance_offset 40B8 Distance Offset P060 Distance Offset - the difference between the transmitter's reference point and the user's preferred reference point. R/W Float 8
MOB_level_offset 40B9 Level Offset P069 Level Offset - the value in Level units to be added to the measured level to produce the required liquid level. R/W Float 8
MOB_lower_blanking 40BA Lower Blanking P063 Lower Blanking distance - the distance up from the Bottom Reference for which all echoes will be ignored. R/W Float 8
urv_nanx 41F2 Test Variable R/W Float 4096
co_gary_arc_data 4209 R/W Float 4096
cop_gary_arc_data 420F R/W Float 4096
Name ID Label Description Type Access Class