Name ID Label Description Type Access Class
KDGM_temperature_reading 4020 Xducer Temp D915 Temperature - Either the value preset in P025, or the value derived from the sensor in the transducer R Float 11
KDGM_target_frequency_reading 4022 Xducer Freq D916 Frequency - The frequency of the pulse train in each transmit burst R Unsigned 11
point 404B R/W Index 4096
SM_auto_cycle 404D Simulation Mode Auto Cycle - The transmitter can be made to simulate the level ramping between minimum and maximum. A complete cycle takes approximately 100 seconds. Auto-cycling may be paused. R/W Enum 8
SM_base_units 402D Base Units Base Units - The transmitter can operate using Base Units of metres, feet or inches. Changing the Base Units will RESET the transmitter and restore it to ex-factory settings in the selected Base Units R/W Enum 8
relay_nr 404F R/W Index 4096
SM_relay1_mode 4051 Relay 1 mode P070 Relay 1 mode - The mode of operation of Relay 1. It may be On, Off or Setpoint R/W Enum 32
SM_relay1_on_point 4054 RL1 ON Point P071 RL 1 ON Point - The value of PV beyond which Relay 1 contact is closed R/W Float 32
SM_relay1_off_point 4057 RL1 OFF Point P072 RL 1 OFF Point - The value of PV beyond which Relay 1 contact is open R/W Float 32
SM_relay2_mode 4052 Relay 2 mode P073 Relay 2 mode - The mode of operation of Relay 2. It may be On, Off or Normal. If set to Normal and P074 and P075 are both 0.0, then the Relay acts as a Fault relay R/W Enum 32