Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
KDGM_temperature_reading | 4020 | Xducer Temp D915 | Temperature - Either the value preset in P025, or the value derived from the sensor in the transducer | R | Float | 11 |
KDGM_target_frequency_reading | 4022 | Xducer Freq D916 | Frequency - The frequency of the pulse train in each transmit burst | R | Unsigned | 11 |
point | 404B | R/W | Index | 4096 | ||
SM_auto_cycle | 404D | Simulation Mode | Auto Cycle - The transmitter can be made to simulate the level ramping between minimum and maximum. A complete cycle takes approximately 100 seconds. Auto-cycling may be paused. | R/W | Enum | 8 |
SM_base_units | 402D | Base Units | Base Units - The transmitter can operate using Base Units of metres, feet or inches. Changing the Base Units will RESET the transmitter and restore it to ex-factory settings in the selected Base Units | R/W | Enum | 8 |
relay_nr | 404F | R/W | Index | 4096 | ||
SM_relay1_mode | 4051 | Relay 1 mode P070 | Relay 1 mode - The mode of operation of Relay 1. It may be On, Off or Setpoint | R/W | Enum | 32 |
SM_relay1_on_point | 4054 | RL1 ON Point P071 | RL 1 ON Point - The value of PV beyond which Relay 1 contact is closed | R/W | Float | 32 |
SM_relay1_off_point | 4057 | RL1 OFF Point P072 | RL 1 OFF Point - The value of PV beyond which Relay 1 contact is open | R/W | Float | 32 |
SM_relay2_mode | 4052 | Relay 2 mode P073 | Relay 2 mode - The mode of operation of Relay 2. It may be On, Off or Normal. If set to Normal and P074 and P075 are both 0.0, then the Relay acts as a Fault relay | R/W | Enum | 32 |
Name | ID | Label | Description | Type | Access | Class |