Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
date | 00A6 | Date (MM/DD/YY): | Data- A data do calendário gregoriano é armazenada no dispositivo de campo. Essa data pode ser usada pelo usuário de qualquer maneira. Não há recomendação específica de uso. | R/W | HartDate | 2048 |
write_protect | 00A7 | Proteção de gravação | Write protect Mode- Indicates whether variables can be written the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. | R/W | Enum | 2048 |
private_label_distributor | 00A8 | Distribuidor | Distribuidor de rótulo particular- Referencia a empresa que é responsável pela distribuição do dispositivo de campo para os clientes | R | Enum | 2048 |
final_assembly_number | 00A9 | ASSEMBLY | Circuit serial number | R/W | Unsigned | 2048 |
xmtr_specific_status_0 | 0FB5 | Status do grupo 1 | Byte 1 do status do dispositivo de campo- Dado que tem a informação do status do dispositivo de campo relacionado à: falhas / alertas / processo do status. | R | BitEnum | 2051 |
xmtr_specific_status_1 | 0FB6 | Status do grupo 2 | Byte 2 do status do dispositivo de campo- Dado que tem a informação do status do dispositivo de campo relacionado à: falhas / alertas / processo do status. | R | BitEnum | 2051 |
pressure_units | 138D | Press.Unit= | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Enum | 8 |
pressure_value | 138E | PV | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 10 |
pressure_percent_range | 138F | PV% | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 34 |
pressure_upper_range_limit | 1393 | URL | Upper Sensor Limit Value- Defines the maximum useable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |
Name | ID | Label | Description | Type | Access | Class |