Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
date | 00A6 | Date (MM/DD/YY): | Fecha: Fecha del calendario gregoriano almacenada en el dispositivo de campo. El usuario puede usar esta fecha de cualquier manera. No hay ningún uso específico recomendado. | R/W | HartDate | 2048 |
write_protect | 00A7 | Write protect | Write protect Mode- Indicates whether variables can be written the Field Device, or whether commands that cause actions, to be performed in the Field Device, can or cannot occur. | R/W | Enum | 2048 |
private_label_distributor | 00A8 | Distribuidor | Private Label Distributor- References the company that is responsible for the distribution of this Field Device to customers | R | Enum | 2048 |
final_assembly_number | 00A9 | ASSEMBLY | Circuit serial number | R/W | Unsigned | 2048 |
xmtr_specific_status_0 | 0FB5 | Status group 1 | Estado específico del dispositivo de campo Byte 1: Datos que tiene el estado del dispositivo de campo información relativa a: fallos/advertencias/estado de los procesos. | R | BitEnum | 2051 |
xmtr_specific_status_1 | 0FB6 | Status group 2 | Estado específico del dispositivo de campo Byte 2: Datos que tiene el estado del dispositivo de campo información relativa a: fallos/advertencias/estado de los procesos. | R | BitEnum | 2051 |
pressure_units | 138D | Press.Unit= | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure. | R/W | Enum | 8 |
pressure_value | 138E | PV | Field Device Variable Value- Digital value that changes magnitude with respect to time with no user intervention. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 10 |
pressure_percent_range | 138F | PV% | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 34 |
pressure_upper_range_limit | 1393 | URL | Upper Sensor Limit Value- Defines the maximum useable value for the Upper Range Value. Pressure- Pressure of the process measured with respect to a reference pressure. | R | Float | 8 |