Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
int_temp_urv | 4100 | InternalTemp URV | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
int_temp_lrv | 4101 | InternalTemp LRV | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
interf_distance_value | 4103 | Interface Distance | Interface Distance - Linear measurement from gauge to interface in tank. | R | Float | 34 |
interf_distance_usl | 4104 | InterfaceDis USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 16 |
interf_distance_lsl | 4105 | InterfaceDis LSL | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 16 |
interf_distance_min_span | 4106 | InterfaceDis Min Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 16 |
interf_distance_urv | 4107 | InterfaceDis URV | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
interf_distance_lrv | 4108 | InterfaceDis LRV | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
interface_value | 410A | Interface Level | Interface - Distance from bottom of tank to interface | R | Float | 34 |
interface_usl | 410B | Interface USL | Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. | R | Float | 16 |
Name | ID | Label | Description | Type | Access | Class |