Loading…
Name ID Label Description Type Access Class
fcf 4020 Flow FCF A 10-character factor that describes the sensitivity of the sensor to mass flow. The first 6 characters are the flow rate, in grams/second, per microsecond of time shift between velocity signals from the sensor. The 2nd four characters are the flow temperature coefficient. R/W ASCII 32
ma_1_cutoff 4645 mA Output Flow Rate Cutoff The mass or volume flow rate below which a milliamp output representing flow indicates zero flow. R/W Float 8
ma_2_cutoff 4687 SV AO cutoff The mass or volume flow rate below which a milliamp output representing flow indicates zero flow. R/W Float 8
sp_volume 4033 Base Volume Unit A standard engineering unit that serves as the volume component in a special unit. R/W Enum 32
sp_volume_time 4034 Base Volume Time A standard unit of time (seconds, minutes, hours, or days) that serves as the time component in a special unit. R/W Enum 32
sp_volume_fact 4035 Conversion Factor A programmable divider for the base volume unit in a special unit. R/W Float 32
sp_volume_rate_text 4036 Flow Label A 1 to 8 character description of a special unit of flow. R/W ASCII 2048
sp_volume_total_text 4037 Total Label A 1 to 8 character description of a special unit of volume, which is based on the special unit of flow to represent total. R/W ASCII 2048
fixfreq 403A Fixed freq A value (in Hertz) that will be indicated on the frequency output for the purpose of a loop test. R/W Float 4096
totctl 4043 Totlizer cntrl Allows the user to Reset, Stop, or Start all totalizers. NOTE - Inventory totals are NOT reset. R/W Enum 4096
Name ID Label Description Type Access Class