Loading…
Loading…
名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
rt_zero | 405F | Zero Value | A value, in microseconds, representing the phase shift between velocity signals from the sensor when measuring zero flow. | 读/写 | 浮点 | 10 |
rt_sigma | 4061 | Standard Deviation | A unitless value which characterizes the amount of deviation between readings during an Auto Zero operation. | 读 | 浮点 | 10 |
fault_index | 4063 | Output Type | 读/写 | 索引 | 4096 | |
LMV_fault_timeout | 4067 | Fault Timeout | This parameter defines the number of seconds for which all outputs will hold their last measured value prior to going to the configured fault state. The default is zero seconds. | 读/写 | 无符号 | 12 |
ao_1_fault_code | 446D | Fault Action | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | 读/写 | 枚举 | 12 |
ao_2_fault_code | 456A | Fault Action | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | 读/写 | 枚举 | 12 |
fo_fault_code | 43A0 | Fault Action | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | 读/写 | 枚举 | 12 |
dig_comm_fault_code | 4594 | Digital Fault Actions | This fault setting applies to Modbus on RS485 and the display. Downscale: Hold process variables at values that are less than the Lower Sensor Limits and stop totalizing. Upscale: Hold process variables at values that are greater than the Upper Sensor Limits and stop totalizing. Not-a-Number: Set all process variables to IEEE NaN. IntZero-All 0: Set all process variables to 0. IntZero-Flow 0: Set flow rate to 0. None: Process variables displayed as measured (NOTE: Use alternative method to detect fault conditions when NONE is selected) | 读/写 | 枚举 | 12 |
ao_1_fault_level | 4566 | Fault Level | This parameter allows you to select the lower or upper mA output level that will indicate a fault condition. The range is 1.0 to 3.6 mA for downscale or 21.0 to 24.0 for upscale. | 读/写 | 浮点 | 64 |
ao_2_fault_level | 456B | Fault Level | This parameter allows you to select the lower or upper mA output level that will indicate a fault condition. The range is 1.0 to 3.6 mA for downscale or 21.0 to 24.0 for upscale. | 读/写 | 浮点 | 64 |
名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |