fo_scaling_method 4024 Frequency Output Scaling Method This parameter allows you to scale the frequency output by using freq=flow, pulses/unit, or units/pulse. This parameter must be sent to the device before you make scaling changes. 读/写 枚举 512
fo_polarity 4029 Frequency Output Polarity This parameter allows you to set the polarity of the frequency output. 读/写 枚举 512
fo_power 467D Power Source This parameter identifies the power source (Internal or External) for the frequency output. 读/写 枚举 512
mass_flow_digital_units 402E Mass Flow Unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. 读/写 枚举 32
mass_flow_digital_value 41C6 Flow Rate 浮点 10
mass_flow_digital_cutoff 4551 Mass Flow Cutoff The mass flow rate below which the frequency/pulse output indicates zero flow, and below which totalizers stop counting. Cutoffs can also be configured for the mA output(s) (the AO cutoffs). An AO cutoff is active only if the process variable assigned to the output is mass flow or volume flow. 读/写 浮点 8
mass_flow_analog_value 464B Mass Flow mA Value 读/写 浮点 66
mass_flow_analog_value_1 4650 Mass Flow mA Value 读/写 浮点 66
mass_flow_analog_upper_limit 467E 模拟量上限 模拟量输出上端点值——定义正常工作条件下每个模拟量输出的上端点。 浮点 64
mass_flow_analog_lower_limit 467F 模拟量下限 模拟量输出下端点值——定义正常工作条件下每个模拟量输出的下端点。 浮点 64