api_thermal_exp_coeff 4168 Thermal Expansion Coefficient This parameter allows you to select the Thermal Expansion Coefficient API. The units are the inverse of the temperature user units. R/W Float 8
api_ref_temp 4169 Reference Temperature This parameter allows you to select the Reference Termperature for API. The units must be the same as the temperature user units. R/W Float 8
api_ctl 416A CTL This parameter displays the Correction of Temperature on a Liquid. R Float 10
enable_api 416B Enable API This parameter allows you to enable/disable the api feature R/W Enum 8
current_ed_curve 416E Active Matrix The Enhanced Density Curve that is currently selected. R/W Enum 2048
api_dens_digital_value 429D Density at Reference Temperature R Float 10
api_dens_analog_value 46C1 Density at Reference Temperature R/W Float 66
api_vol_flow_digital_value 42A3 Flow R Float 10
api_vol_flow_analog_value 4898 Volume Flow at Ref Temperature R/W Float 66
api_vtot_digital_value 4526 Total R Float 10