Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
vol_flow_p_u | 46A4 | Pulses/Unit | This parameter allows you to scale the frequency output in terms of the number of pulses per unit of flow. | R/W | Float | 512 |
vol_flow_u_p | 46A5 | Units/Pulse | This parameter allows you to scale the frequency output in terms of the number of units of flow required to generate one pulse. | R/W | Float | 512 |
vtot_digital_units | 4628 | Vol flo totl unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. | R | Enum | 32 |
vtot_digital_value | 4522 | Total | R | Float | 10 | |
vinv_digital_value | 4529 | Inventory | R | Float | 10 | |
pres_digital_units | 4093 | Pressure Unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit | R/W | Enum | 32 |
pres_digital_value | 4537 | External Pressure | R | Float | 10 | |
pres_analog_value | 46AA | AO | R/W | Float | 66 | |
pres_analog_upper_limit | 46AB | Límite sup. analóg. | Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions | R | Float | 64 |
pres_analog_lower_limit | 46AC | Límite inf. analóg. | Analog Output Lower Endpoint Value- Defines the lower endpoint, of the respective Analog Output, for normal operating conditions | R | Float | 64 |
Name | ID | Label | Description | Type | Access | Class |