Loading…
Name ID Label Description Type Access Class
burst_variable_code_4 0FFB Field Device Variable 4 Index into Dynamic Variables Array- Is the fourth of an array of addresses, whose value identified by the Field Device Variable Code R/W Index 128
burst_command_number 0FFD Option Burst Option- Selects the variable(s) that will be Bursted if Burst Mode is enabled. R/W Enum 128
burst_mode_select 0FFF Mode Burst Mode Select- Selects the mode for the Burst Mode functionality. If Burst is enabled the Field Device will generate HART messages on the Link without individual requests from the Host. W Enum 128
ED_2_refTemp 45CC Reference Temperature The reference temperature of the fluid R/W Float 32
ED_3_refTemp 45D2 Reference Temperature The reference temperature of the fluid R/W Float 32
ED_4_refTemp 45D8 Reference Temperature The reference temperature of the fluid R/W Float 32
ED_5_refTemp 45DE Reference Temperature The reference temperature of the fluid R/W Float 32
ED_6_refTemp 45E4 Reference Temperature The reference temperature of the fluid R/W Float 32
ED_2_sgWaterRefTemp 45CD Water Reference Temperature Water Reference Temperature R/W Float 32
ED_3_sgWaterRefTemp 45D3 Water Reference Temperature Water Reference Temperature R/W Float 32
Name ID Label Description Type Access Class