Name ID Label Description Type Access Class
vol_flow_digital_units 4066 Volume Flow Unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. R/W Enum 32
vol_flow_digital_value 4067 Volume Flow Rate R Float 10
vol_flow_digital_cutoff 4069 Volume Flow Cutoff The volume flow rate below which the frequency/pulse output indicates zero flow,and below which totalizers stop counting. Cutoffs can also be configured for the mA output(s) (the mA output cutoffs). An mA output cutoff is active only if the process variable assigned to the output is mass flow or volume flow. R/W Float 8
vol_flow_analog_value 406A Volume Flow mA Value R/W Float 66
vol_flow_analog_upper_limit 406B mA Output Upper Limit Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions R Float 64
vol_flow_analog_lower_limit 406C mA Output Lower Limit mA output Lower Endpoint Value- Defines the lower endpoint, of the respective mA output, for normal operating conditions. R Float 64
vol_flow_additional_analog_damping 406D Added Damping mA output Added Damping Value- Damping time constant applied the mA output. The units of this variable are always in seconds. R/W Float 32
vol_flow_percent_range 406E Primary Variable Percent Range Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
vol_flow_upper_range_value 406F Volume Flow Upper Range Value Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
vol_flow_lower_range_value 4070 Volume Flow Lower Range Value Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
Name ID Label Description Type Access Class