Name ID Label Description Type Access Class
live_zero_vol_flow_upper_range_value 4507 Mass Flow Upper Range Value Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
live_zero_vol_flow_lower_range_value 4508 Mass Flow Lower Range Value Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
live_zero_vol_flow_analog_value_1 4509 Mass Flow mA Value R/W Float 66
live_zero_vol_flow_additional_analog_damping_1 450A Added Damping mA output Added Damping Value- Damping time constant applied the mA output. The units of this variable are always in seconds. R/W Float 32
live_zero_vol_flow_percent_range_1 450B Secondary Variable Percent Range Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
live_zero_vol_flow_upper_range_value_1 450C Mass Flow Upper Range Value Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
live_zero_vol_flow_lower_range_value_1 450D Mass Flow Lower Range Value Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
live_zero_vol_flow_upper_sensor_limit 450E Mass Flow Upper Sensor Limit Upper Sensor Limit Value- Defines the maximum usable value for the Upper Range Value. R Float 8
live_zero_vol_flow_lower_sensor_limit 450F Mass Flow Lower Sensor Limit Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. R Float 8
live_zero_vol_flow_minimum_span 4510 Mass Flow Minimum Span Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. R Float 8