名称 ID 标签 描述 类型 访问 分类
flow_switch_setpoint 41DE Setpoint This parameter can be used to trigger a discrete output when the mass flow rate exceeds the configured setpoint. There is a fixed hysteresis of 5% for this setpoint. 读/写 浮点 16
do1_assignment 41DF Assignment This parameter identifies which condition the discrete output will act upon. 读/写 枚举 1024
do1_state 41E0 离散输出 1 状态 This parameter identifies the state of the discrete output. 读/写 枚举 2
do1_polarity 41E1 离散输出 1 极性 This parameter allows you to set the polarity of the discrete output. 读/写 枚举 1024
do1_FaultIndication 4389 Fault Action 读/写 枚举 1024
do2_assignment 41E2 Assignment This parameter identifies which condition the discrete output will act upon. 读/写 枚举 1024
do2_state 41E3 离散输出 2 状态 This parameter identifies the state of the discrete output. 读/写 枚举 2
do2_polarity 41E4 离散输出 2 极性 This parameter allows you to set the polarity of the discrete output. 读/写 枚举 1024
do2_FaultIndication 438A 故障动作 读/写 枚举 1024
do3_assignment 41E5 分配 This parameter identifies which condition the discrete output will act upon. 读/写 枚举 1024