名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
pc4_setpointA | 4182 | Setpoint A | The first programmable value of a process variable in which the Discrete Events compares with. | 读/写 | 浮点 | 16 |
pc4_setpointB | 4183 | Setpoint B | The second programmable value of a process variable in which the Discrete Events compares with. | 读/写 | 浮点 | 16 |
pc4_varcode | 4184 | Variable | Assigns a process variable to the Discrete Events. | 读/写 | 索引 | 16 |
pc4_type | 4185 | 事件类型 | Determines the type of comparison the Discrete Events is going to perform. | 读/写 | 枚举 | 1024 |
pc5_setpointA | 4187 | Setpoint A | The first programmable value of a process variable in which the Discrete Events compares with. | 读/写 | 浮点 | 16 |
pc5_setpointB | 4188 | Setpoint B | The second programmable value of a process variable in which the Discrete Events compares with. | 读/写 | 浮点 | 16 |
pc5_varcode | 4189 | Variable | Assigns a process variable to the Discrete Events. | 读/写 | 索引 | 16 |
pc5_type | 418A | 事件类型 | Determines the type of comparison the Discrete Events is going to perform. | 读/写 | 枚举 | 1024 |
pm_index | 41BD | Process Monitor Num | 读/写 | 索引 | 4096 | |
pm1_varcode | 4196 | Position 1 | This parameter allows you to select the process variable that will appear on the Process Monitor screen. | 读/写 | 枚举 | 2048 |