Loading…
Name ID Label Description Type Access Class
flow_switch_setpoint 41DE Setpoint This parameter can be used to trigger a discrete output when the mass flow rate exceeds the configured setpoint. There is a fixed hysteresis of 5% for this setpoint. R/W Float 16
do1_assignment 41DF Assignment This parameter identifies which condition the discrete output will act upon. R/W Enum 1024
do1_state 41E0 Состояние дискретного выхода 1 This parameter identifies the state of the discrete output. R/W Enum 2
do1_polarity 41E1 Полярность дискретного выхода 1 This parameter allows you to set the polarity of the discrete output. R/W Enum 1024
do1_FaultIndication 4389 Fault Action R/W Enum 1024
do2_assignment 41E2 Assignment This parameter identifies which condition the discrete output will act upon. R/W Enum 1024
do2_state 41E3 Состояние дискретного выхода 2 This parameter identifies the state of the discrete output. R/W Enum 2
do2_polarity 41E4 Полярность дискретного выхода 2 This parameter allows you to set the polarity of the discrete output. R/W Enum 1024
do2_FaultIndication 438A Действие сбоя R/W Enum 1024
do3_assignment 41E5 Назначение This parameter identifies which condition the discrete output will act upon. R/W Enum 1024
Name ID Label Description Type Access Class