Loading…
Name ID Label Description Type Access Class
mmi_flange_type 4114 Sensor Flange Configuration information identifying the flange material used with the sensor. Informational purposes only - does not affect flowmeter operation. R/W Enum 2048
liner_matl 4115 Обкладка трубки Configuration information identifying any liner material used with the sensor. Informational purposes only - does not affect flowmeter operation. R/W Enum 2048
sensor_model 4116 Sensor Model Configuration information identifying the sensor model installed. Informational purposes only - does not affect flowmeter operation. R/W PackedAscii 2048
sensor_matl 4117 Увлажненный материал трубки Configuration information identifying the material of which the sensor is constructed. Informational purposes only - does not affect flowmeter operation. R/W Enum 2048
sens_type_code 4118 Type This parameter indicates which type of sensor is being used for process measurement. R/W Enum 8
slughi 4119 Slug High Limit A programmable high limit on density, which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. R/W Float 8
sluglo 411A Slug Low Limit A programmable low limit on density, which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. R/W Float 8
slug_duration 411B Slug Duration A programmable time period, from 0.00 to 60.00 seconds, during which outputs representing flow hold their last measured value before indicating slug flow. R/W Float 12
flocal 411C Калиб. расх. A 10-character factor that describes the sensitivity of the sensor to mass flow. The first 6 characters are the flow rate, in grams/second, per microsecond of time shift between velocity signals from the sensor. The 2nd four characters are the flow temperature coefficient. R/W ASCII 32
fcf 411D Flow FCF A 10-character factor that describes the sensitivity of the sensor to mass flow. The first 6 characters are the flow rate, in grams/second, per microsecond of time shift between velocity signals from the sensor. The 2nd four characters are the flow temperature coefficient. R/W ASCII 32
Name ID Label Description Type Access Class