Name ID Label Description Type Access Class
vol_flow_p_u 407A Pulses/Unit This parameter allows you to scale the frequency output in terms of the number of pulses per unit of flow. R/W Float 512
vol_flow_u_p 407B Units/Pulse This parameter allows you to scale the frequency output in terms of the number of units of flow required to generate one pulse. R/W Float 512
vtot_digital_units 407E Unid total fluxo vol Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. R Enum 32
vtot_digital_value 407F Total de volume R Float 10
vinv_digital_value 4081 Inventory R Float 10
pres_digital_units 4083 Pressure Unit Unidade de variável de dispositivo de campo - Unidade de engenharia a ser mostrada com representação de valor digital, intervalo mínimo, valor de taxa superior, valor de taxa inferior, limite inferior do sensor e limite superior do sensor. R/W Enum 32
pres_digital_value 4084 Pressão externa R Float 10
pres_analog_value 4085 saída de mA R/W Float 66
pres_analog_upper_limit 4086 Limite sup saída mA Valor de endpoint superior de saída analógica – Define o endpoint superior darespectiva saída analógica para as condições de operação normal R Float 64
pres_analog_lower_limit 4087 Limite inf saída mA Valor do ponto final inferior da saída mA - Define o ponto final inferior da respectiva saída mA para condições normais de operação. R Float 64
Name ID Label Description Type Access Class