Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
vol_flow_digital_units | 4066 | Volume Flow Unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. | R/W | Enum | 32 |
vol_flow_digital_value | 4067 | Volume Flow Rate | R | Float | 10 | |
vol_flow_digital_cutoff | 4069 | Volume Flow Cutoff | The volume flow rate below which the frequency/pulse output indicates zero flow,and below which totalizers stop counting. Cutoffs can also be configured for the mA output(s) (the mA output cutoffs). An mA output cutoff is active only if the process variable assigned to the output is mass flow or volume flow. | R/W | Float | 8 |
vol_flow_analog_value | 406A | Volume Flow mA Value | R/W | Float | 66 | |
vol_flow_analog_upper_limit | 406B | mA Output Upper Limit | Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions | R | Float | 64 |
vol_flow_analog_lower_limit | 406C | mA Output Lower Limit | mA output Lower Endpoint Value- Defines the lower endpoint, of the respective mA output, for normal operating conditions. | R | Float | 64 |
vol_flow_additional_analog_damping | 406D | Added Damping | mA output Added Damping Value- Damping time constant applied the mA output. The units of this variable are always in seconds. | R/W | Float | 32 |
vol_flow_percent_range | 406E | Primary Variable Percent Range | Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. | R | Float | 34 |
vol_flow_upper_range_value | 406F | Volume Flow Upper Range Value | Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
vol_flow_lower_range_value | 4070 | Volume Flow Lower Range Value | Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. | R/W | Float | 32 |
Name | ID | Label | Description | Type | Access | Class |