Name ID Label Description Type Access Class
dens_digital_units 404F Density Unit Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. R/W Enum 32
dens_digital_value 4050 Density R Float 10
dens_digital_cutoff 4052 Density Cutoff The density below which the density indicates zero. R/W Float 8
dens_analog_value 4053 Density mA Value R/W Float 66
dens_analog_upper_limit 4054 mA Output Upper Limit Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions R Float 64
dens_analog_lower_limit 4055 mA Output Lower Limit mA output Lower Endpoint Value- Defines the lower endpoint, of the respective mA output, for normal operating conditions. R Float 64
dens_additional_analog_damping 4056 Added Damping mA output Added Damping Value- Damping time constant applied the mA output. The units of this variable are always in seconds. R/W Float 32
dens_percent_range 4057 Primary Variable Percent Range Percent of Range- Variable that tracks the Digital Value representation with respect to the range defined by the Lower Range Value and Upper Range Value, for normal operating modes. The units of this variable are always in percent. R Float 34
dens_upper_range_value 4058 Density Upper Range Value Upper Range Value- Defines the operational endpoint from which the Analog Value, and the 100% point of the Percent Range are derived. In addition, the Upper Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32
dens_lower_range_value 4059 Density Lower Range Value Lower Range Value- Defines the operational endpoint from which the Analog Value, and the 0% point of the Percent Range are derived. In addition, the Lower Range Value defines an operational endpoint which the alarms associated with the Analog Value, and the alarms associated with the Digital Value representation are derived. R/W Float 32