Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
api_ctl | 40BC | CTL | This parameter displays the Correction of Temperature on a Liquid. | R | Float | 10 |
ext_temp_digital_value | 40BF | External Temperature | R | Float | 10 | |
ed_std_vol_flow_digital_value | 40C1 | Flow Rate | R | Float | 10 | |
ed_std_vol_flow_analog_value | 40C2 | Enhanced Density Standard Volume Flow | R/W | Float | 66 | |
ed_std_vol_flow_analog_value_1 | 40C3 | Enhanced Density Standard Volume Flow | R/W | Float | 66 | |
ed_volume_flow_digital_damping | 4371 | Flow Damping | Damping Value- Damping time constant applied to both the Digital Value representation and Analog Value of the respective mA output. The units of this variable are always in seconds. | R/W | Float | 32 |
ed_std_vtot_digital_value | 40C6 | Total | R/W | Float | 10 | |
ed_std_vinv_digital_value | 40C8 | Inventory | R | Float | 10 | |
ed_net_vol_flow_digital_value | 40CA | Flow Rate | R | Float | 10 | |
ed_net_vol_flow_analog_value | 40CB | Enhanced Density Net Volume Flow | R/W | Float | 66 | |
Name | ID | Label | Description | Type | Access | Class |