Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
mass_flow_hzfreq | 4026 | Freq factr | The number of cycles, in Hertz, that equal a proportional flow rate represented by the frequency/pulse output. | R/W | Float | 512 |
mass_flow_hzrate | 4027 | Rate factr | The flow rate that equals a set frequency if the frequency output represents mass or volume flow; or the mass or volume total that equals a set number of pulses if the frequency output represents mass or volume total. | R/W | Float | 512 |
mass_flow_p_u | 4029 | Pulses/Unit | This parameter allows you to scale the frequency output in terms of the number of pulses per unit of flow. | R/W | Float | 512 |
mass_flow_u_p | 402A | Units/Pulse | This parameter allows you to scale the frequency output in terms of the number of units of flow required to generate one pulse. | R/W | Float | 512 |
temp_digital_units | 4036 | Temp unit | Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. | R/W | Enum | 32 |
temp_digital_value | 4037 | Temp | R | Float | 10 | |
temp_analog_value | 4038 | Temp anlog valu | R/W | Float | 66 | |
temp_analog_upper_limit | 4039 | Anlog upr limit | Analog Output Upper Endpoint Value- Defines the upper endpoint, of the respective Analog Output, for normal operating conditions | R | Float | 64 |
temp_analog_lower_limit | 403A | Anlog lor limit | Analog Output Lower Endpoint Value- Defines the lower endpoint, of the respective Analog Output, for normal operating conditions | R | Float | 64 |
temp_additional_analog_damping | 403B | Added damp | Analog Output Added Damping Value- Damping time constant applied the Analog Output. The units of this variable are always in seconds. | R/W | Float | 32 |
Name | ID | Label | Description | Type | Access | Class |