Loading…
名称 ID 标签 描述 类型 访问 分类
operatingMode 0870 操作模式1 特定现场设备操作模式1——现场设备中一种可能的操作模式。 枚举 2049
extended_fld_device_status 0807 Extended Device Status Provides additional Device Status information 位枚举 0
serial_number 4008 传感器序列号 传感器序列号——识别数值表示或现场设备变量来源的传感器。 读/写 无符号 2048
met_direct 4009 流向 This parameter enables the user to determine whether the outputs and totalizers will indicate forward, reverse, bi-directional or absolute value flow. 读/写 枚举 32
output_opt_brd 400A Output Opt. Brd. This parameter represents the various types of output option boards that are available. 枚举 2048
totctl 400B 累加器控制 Allows the user to Reset, Stop, or Start all totalizers. NOTE - Inventory totals are NOT reset. 读/写 枚举 4096
feature_key 400D Features The type of log to be reset. 位枚举 2048
current_ed_curve 400E Current ED Curve The Enhanced Density Curve that is currently selected. 读/写 枚举 2048
mass_flow_digital_units 400F 质量流量单位 Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. 读/写 枚举 32
mass_flow_digital_value 4011 Mass flo 浮点 10
名称 ID 标签 描述 类型 访问 分类