Loading…
Loading…
Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
mass_flow_lower_sensor_limit | 401F | Mass Flow Lower Sensor Limit | Lower Sensor Limit Value- Defines the minimum usable value for the Lower Range Value. | R | Float | 8 |
mass_flow_minimum_span | 4020 | Mass Flow Minimum Span | Minimum Span Value- Defines the smallest allowable difference between the Upper Range Value and the Lower Range Value. | R | Float | 8 |
mass_flow_hzfreq | 4021 | Frequency Factor | The number of cycles, in Hertz, that equal a proportional flow rate represented by the frequency/pulse output. | R/W | Float | 512 |
mass_flow_hzrate | 4023 | Rate Factor | The flow rate that equals a set frequency if the frequency output represents mass or volume flow; or the mass or volume total that equals a set number of pulses if the frequency output represents mass or volume total. | R/W | Float | 512 |
mass_flow_p_u | 4024 | Pulses/Unit | This parameter allows you to scale the frequency output in terms of the number of pulses per unit of flow. | R/W | Float | 512 |
mass_flow_u_p | 4025 | Units/Pulse | This parameter allows you to scale the frequency output in terms of the number of units of flow required to generate one pulse. | R/W | Float | 512 |
massflowClassificationCode | 4D2D | Mass Flow Classification | Classification- Indicates the unit code expansion table used for a particular dynamic or device variable. | R | Enum | 0 |
massflowFamily | 4D2E | Mass Flow Family | Device Family- Indicates the family (i.e, pressure, temperature, flow, etc.) that the device variable belongs. | R | Enum | 2048 |
massflowPDQ | 4CD8 | Status | Process Data Quality- Indicates the overall process data quality of the device variable value. | R | Enum | 10 |
massflowLS | 4D2F | Mass Flow LS | Limit Status- Indicates whether the device variable is limited (i.e., not responding to a process). | R | Enum | 10 |
Name | ID | Label | Description | Type | Access | Class |