Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
DCoef | 40E3 | TC | The percent change in the elasticity of the flow tubes around the bending axis per 100 degrees Celsius. | R/W | Float | 8 |
DT | 40E4 | DT | The percent change in the elasticity of the flow tubes around the bending axis per 100 degrees Celsius. | R/W | Float | 8 |
alarm_number | 40F6 | Event num | R/W | Index | 4096 | |
alarm1_type | 40EA | Event 1 Type | Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. | R/W | Enum | 1024 |
alarm2_type | 40EF | Event 2 Type | Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. | R/W | Enum | 1024 |
alarm1_setpoint | 40E6 | Event 1 Setpoint | A programmable value of a process variable at which an output set to represent event 1 or event 2 switches states. | R/W | Float | 16 |
alarm2_setpoint | 40ED | Event 2 Setpoint | A programmable value of a process variable at which an output set to represent event 1 or event 2 switches states. | R/W | Float | 16 |
alarm1_varcode | 40E8 | Event 1 Variable | Assigns a process variable to event 1 or event 2. | R/W | Index | 16 |
alarm2_varcode | 40EE | Event 2 Variable | Assigns a process variable to event 1 or event 2. | R/W | Index | 16 |
rt_freq | 40F7 | Имеющийся частотный выход | The frequency, in Hertz, presently being indicated on the frequency output. | R | Float | 514 |
Name | ID | Label | Description | Type | Access | Class |