Loading…
名称 ID 标签 描述 类型 访问 分类
flow_switch_hysteresis 4588 Hysteresis (0.1-10.0) If the hysteresis is set to 5%, no change of the Discrete Output state occurs when the flow rate is within +-5% of the setpoint. If the setpoint is 100 lb/min and the first reading is below 95 lb/min, the flow switch turns On and will stay On until the flow rate rises above 105 lb/min. At this point it turns Off, and will stay off until the flow rate drops below 95 lb/min. 读/写 浮点 8
chan_a 412E 分配 This parameter identifies the physical output channel to be configured. Channel A is terminals 1 and 2, Channel B is terminals 3 and 4, and Channel C is terminals 5 and 6. 枚举 64
chan_b 4006 分配 This parameter identifies the physical output channel to be configured. Channel A is terminals 1 and 2, Channel B is terminals 3 and 4, and Channel C is terminals 5 and 6. 读/写 枚举 64
chan_c 412F 分配 This parameter identifies the physical output channel to be configured. Channel A is terminals 1 and 2, Channel B is terminals 3 and 4, and Channel C is terminals 5 and 6. 枚举 64
current_ed_curve 4238 活动矩阵 The Enhanced Density Curve that is currently selected. 读/写 枚举 2048
ed_std_vol_flow_digital_value 4239 Flow Rate 浮点 10
ed_std_vol_flow_analog_value 423A Temperature-Corrected Volume Flow Rate (Concentration) 读/写 浮点 66
ed_std_vol_flow_analog_value_1 423B Temperature-Corrected Volume Flow Rate (Concentration) 读/写 浮点 66
ed_std_vtot_digital_value 423C Total 浮点 10
ed_std_vinv_digital_value 423D 库存量 浮点 10
名称 ID 标签 描述 类型 访问 分类