名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |
---|---|---|---|---|---|---|
alarm2_type | 40EF | Event 2 Type | Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. | 读/写 | 枚举 | 1024 |
alarm1_setpoint | 40E6 | Event 1 Setpoint | A programmable value of a process variable at which an output set to represent event 1 or event 2 switches states. | 读/写 | 浮点 | 16 |
alarm2_setpoint | 40ED | Event 2 Setpoint | A programmable value of a process variable at which an output set to represent event 1 or event 2 switches states. | 读/写 | 浮点 | 16 |
alarm1_varcode | 40E8 | Event 1 Variable | Assigns a process variable to event 1 or event 2. | 读/写 | 索引 | 16 |
alarm2_varcode | 40EE | Event 2 Variable | Assigns a process variable to event 1 or event 2. | 读/写 | 索引 | 16 |
rt_freq | 40F7 | Present Frequency Output | The frequency, in Hertz, presently being indicated on the frequency output. | 读 | 浮点 | 514 |
unknown_serial_number | 4049 | Sensor Serial Number | 读/写 | 无符号 | 4096 | |
unknown_float | 4044 | 读/写 | 浮点 | 4096 | ||
unknown_units | 40F8 | 单位 | 读/写 | 枚举 | 4096 | |
mass_rate_factor | 40F9 | Mass Factor | A value, between 0.8 and 1.2, that will act as a multiplier for the mass flow rate. | 读/写 | 浮点 | 8 |
名称 | ID | 标签 | 描述 | 类型 | 访问 | 分类 |