Name | ID | Label | Description | Type | Access | Class |
---|---|---|---|---|---|---|
tempcal | 40BF | Temperature Calibration Factor | A 14-character factor that describes the slope and offset of the linear output representing flow tube temperature. | R/W | ASCII | 32 |
rt_zero | 40C0 | Zero Value | A value, in microseconds, representing the phase shift between velocity signals from the sensor when measuring zero flow. | R/W | Float | 10 |
zero_offset_units | 40C1 | Zero units | Units for zero offset - always microseconds. | R/W | Unsigned | 32 |
rt_sigma | 40C2 | Standard Deviation | A unitless value which characterizes the amount of deviation between readings during an Auto Zero operation. | R | Float | 10 |
fault_index | 40C3 | Output Type | R/W | Index | 4096 | |
LMV_fault_timeout | 40C5 | Fault Timeout | This parameter defines the number of seconds for which all outputs will hold their last measured value prior to going to the configured fault state. The default is zero seconds. | R/W | Unsigned | 12 |
ao_1_fault_code | 40CA | Ação de falha | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | R/W | Enum | 12 |
ao_2_fault_code | 40CE | Ação de falha | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | R/W | Enum | 12 |
fo_fault_code | 40D0 | Ação de falha | Downscale: Milliamp outputs that indicate flow go to the configured limit, the frequency output equals 0 Hz. Upscale: Milliamp and frequency outputs go to the configured limit. Internal zero: Flow outputs indicate zero flow. | R/W | Enum | 12 |
dig_comm_fault_code | 40D2 | Ação de falha | This fault setting applies to Modbus on RS485 and the display. Downscale: Hold process variables at values that are less than the Lower Sensor Limits and stop totalizing. Upscale: Hold process variables at values that are greater than the Upper Sensor Limits and stop totalizing. Not-a-Number: Set all process variables to IEEE NaN. IntZero-All 0: Set all process variables to 0. IntZero-Flow 0: Set flow rate to 0. None: Process variables displayed as measured (NOTE: Use alternative method to detect fault conditions when NONE is selected) | R/W | Enum | 12 |
Name | ID | Label | Description | Type | Access | Class |