Name ID Label Description Type Access Class
sensor_matl 40A3 Tube Wetted Material Configuration information identifying the material of which the sensor is constructed. Informational purposes only - does not affect flowmeter operation. R/W Enum 2048
sp_mass 40A4 Base Unit A standard engineering unit that serves as the mass component in a special unit. R/W Enum 32
sp_mass_time 40A5 Base Time A standard unit of time (seconds, minutes, hours, or days) that serves as the time component in a special unit. R/W Enum 32
sp_mass_fact 40A6 Conversion Factor A programmable divider for the base mass unit in a special unit. R/W Float 32
sp_mass_rate_text 40A7 Flow Label A 1 to 8 character description of a special unit of flow. R/W ASCII 2048
sp_mass_total_text 40A8 Total Label A 1 to 8 character description of a special unit of mass, which is based on the special unit of flow to represent total. R/W ASCII 2048
met_direct 40A9 Flow Direction This parameter enables the user to determine whether the outputs and totalizers will indicate forward, reverse, bi-directional or absolute value flow. R/W Enum 32
slughi 40AA Slug High Limit A programmable high limit on density, which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. R/W Float 8
sluglo 40AB Slug Low Limit A programmable low limit on density, which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. R/W Float 8
slug_duration 40AC Slug Duration A programmable time period, from 0.00 to 60.00 seconds, during which outputs representing flow hold their last measured value before indicating slug flow. R/W Float 12