Loading…
Name ID Label Description Type Access Class
flocal 40AD Durchflu?kalibrierfaktor A 10-character factor that describes the sensitivity of the sensor to mass flow. The first 6 characters are the flow rate, in grams/second, per microsecond of time shift between velocity signals from the sensor. The 2nd four characters are the flow temperature coefficient. R/W ASCII 32
fcf 40AF Flow FCF A 10-character factor that describes the sensitivity of the sensor to mass flow. The first 6 characters are the flow rate, in grams/second, per microsecond of time shift between velocity signals from the sensor. The 2nd four characters are the flow temperature coefficient. R/W ASCII 32
ma_1_cutoff 4028 mA Ausgang Durchflussabschaltung Schleichmengenunterdr?ckung: Der Stromausgang zeigt Null f?r Werte kleiner der gew?hlten Durchflu?rate an. R/W Float 8
ma_2_cutoff 402A mA Ausgang Durchflussabschaltung Schleichmengenunterdr?ckung: Der Stromausgang zeigt Null f?r Werte kleiner der gew?hlten Durchflu?rate an. R/W Float 8
sp_volume 40B0 Basiseinheit Grundeinheit f?r Volumen zum Aufbau einer Spezialeinheit. R/W Enum 32
sp_volume_time 40B1 Basiszeit Grundeinheit f?r Zeit (Sekunden, Minuten, Stunden oder Tage) zum Aufbau einer Spezialeinheit. R/W Enum 32
sp_volume_fact 40B2 Conversion Factor A programmable divider for the base volume unit in a special unit. R/W Float 32
sp_volume_rate_text 40B3 Flow Label Text f?r Durchflu?-Spezialeinheit (Volumen). Maximal 8 Zeichen. R/W ASCII 2048
sp_volume_total_text 40B4 Total Label Text f?r Z?hler-Spezialeinheit (Volumen), die auf der Durchflu?-Spezialeinheit (Volumen) basiert. R/W ASCII 2048
fixfreq 40B5 Festwert Frequenz Me?kreistest: Frequenz in Hz, auf die der Impuls-/Frequenzausgang gesetzt werden kann. R/W Float 4096
Name ID Label Description Type Access Class